THERMAL PROTECTION:

The PRO5000 is equipped with a unique protection system
that continually monitors the temperature of the output
devices and takes corrective action to prevent damage to
the amplifier as a result of overheating. Under most con-
ditions, the PRO5OOO’s cooling system can dissipate the
heat required to maintain safe operating temperatures, and
the unit will play continuously. If the amplifier is driven at
high volumes into speakers with an impedance of less than

4 ohms, and/or there is inadequate ventilation, the heatsink

could heat to a level that would cause the protection
circuitry to shut the unit off for a short time (normally less

than 1 minute), to prevent damage. The PRO5000 will
return to normal operation, and if the overheating condition
is still present the cycle will repeat. In this case, check the
surroundings of the amplifier to ensure sufficient air flow
into and out of the vents. Otherwise, check the load im-

pedance connected to the outputs to see if it is far below 4
ohms.

FUSES:

The PRO5000 is supplied with an internal 

15 ampere Slo-

Blo AC line fuse. For continued protection, replace this
fuse only with the same type and rating. The fuse is located

on the inside wall near the power switch.

The four power supply fuses on the printed circuit board are
there to protect the output devices if excessive current is
drawn (e.g. a short circuit across the output terminals).
Replace only with 

10 ampere 3AG type fuses

.

FACTORY SERVICE AND LIMITED

WARRANTY

If you encounter any difficulty or have any questions

concerning your PRO5000 Amplifier, please call our
Customer service Department weekdays, 8 a.m. to 3:30
p.m., Mountain Standard Time, at 602-967-3565.

Should you have any doubts as to whether the amplifier is
malfunctioning and requires service, please call us before
sending in for repair. All units being returned (regardless of
warranty status) must receive a Return Authorization (RA)
number. In addition, we can offer troubleshooting assistance
that may simplify or even eliminate the need for factory

service.

The Hafler PRO5000 Amplifier is warranted to the original
owner (non-transferrable) for three years form the date of
purchase, including parts, labor, and return shipping costs
within the continental United States, Alaska, and Hawaii.

This warranty applies only to products 

sold 

in the United

States of America.

For warranties outside the U.S.A., pleasecontact your local
agent.

It is the owner’s responsibility to pay shipping (preferably
United Parcel Service, UPS) to the factory: collect ship-

ments will not be accepted. Units under warranty should be
accompanied by a copy of the dated Bill of Sale. Use the
original carton and all packing material, with the RA
number clearly marked on the outside of the package. Be

sure to include a return address, the RA number, a daytime

telephone number, and a brief description of the difficulty,
including whether it occurs continuously or intermittently.

This warranty gives you specific legal rights. You may also
have other rights which vary from state to state.

-10-

Summary of Contents for PRO5000

Page 1: ...Hafler INSTALLATION fbd OPERATION Please refer to this serial number in all communications regarding this equipment ...

Page 2: ...et op eration and a variety of simple yet effective protection systems Above all however the PRO5000 maintains the well known Hafler tradition of superior sounding power amplifiers OVERVIEW OF AMPLIFIER The PRO5000 is a standard two rack height fan cooled design utilizing fully complimentary drive circuits and lateral type MOSFET output transistors The amplifier has full subtractor balanced input ...

Page 3: ...nd placed so that it is not in danger of being pinched or cut as in under a rug aroundatightcorner etc 10 11 12 13 14 15 Grounding and Polarization The power supply cord is of a polarized type designed toreducetheriskofelectricshocksustainedfromalive cabinet It is assumed to be of a suitable length for most uses of the equipment The use of extension cords and power strips is discouraged unless the...

Page 4: ... as to provide some protection against voltage surges and built up static charges Section 8 10 of the National Electrical Code ANSl NFPA No 70 1984 provides information with respect to the proper grounding of the mast and supporting structure grounding of the lead in wire to an antenna discharge unit size of grounding conductors location of antenna discharge unit connections to groundingelectrodes...

Page 5: ...ine voltage than what is supplied in an attempt to obtain greater output power Such an attempt will very likely damage parts in the amplifier not rated for the higher voltages that will result and the warranty will be voided A 3 wire grounded power cord is supplied It must be connected to a properly grounded earthed AC receptacle for safety Do not break off the ground pin on the plug to avoid usin...

Page 6: ...rminal is the connection No connections should be made to either black output terminal in this configuration OPERATION APPLYING POWER Standard practice is to turn power amplifiers on last and off first in the chain of electronics This minimizes the likeli hood of damage to the load from turn on and turn off transients generated by source equipment The PROS000 provides built in protection from such...

Page 7: ...TION T201 Transformer DB201 Diode Bridge F201 10A Fuse SW201 Power Switch S W 2 0 2 Grounding Switch C201 C202 Capacitor 20 000 C203 Capacitor 01 UL approved C204 Capacitor 01 TS201 Inrush Limiter J201 J203 Binding Post Black J202 J204 Binding Post Red CLIP DETECTOR CHASSIS PARTS LIST PART TT PRO5000 SSH 609 FS 010 SWH 144 SWH 103 CER 209 CD 103A CD 103 20 SSH 618 CCH 110B CCH 11OR 6 ...

Page 8: ......

Page 9: ......

Page 10: ...2A SS 102A ss 113 RMP 4 2431 RMP 4 4752 RC 4 470 RC 4 470 RC 4 680 RC 4 470 RC 4 470 RMP 4 1001 RMP 4 1001 RC 4 682 RMP 4 4752 RMP 4 2431 RC 4 271 R49 Rl4 R50 Rl5 R51 Rl6 R52 R l 7 R53 Rl8 R54 Rl9 R55 RZO R56 R21 R57 R22 R58 R 2 3 R59 R 2 4 R60 R25 R61 R26 R62 R 2 7 R63 R28 R64 R29 R65 R30 R66 R31 R67 R 3 2 R68 R33 R69 R 3 4 R70 R35 R71 R72 R73 R74 R75 R76 R77 R78 R79 R80 R81 R82 R85 R83 R86 R84 R...

Page 11: ...with 10 ampere 3AG type fuses FACTORY SERVICE AND LIMITED WARRANTY If you encounter any difficulty or have any questions concerning your PRO5000 Amplifier please call our Customer service Department weekdays 8 a m to 3 30 p m Mountain Standard Time at 602 967 3565 Should you have any doubts as to whether the amplifier is malfunctioning and requires service please call us before sending in for repa...

Reviews: