Connecting the connectors 

Wire ends have to be stripped to a maximum of 5,5mm (7/32 inch) to control the depth of the wire into 
the contact. (Wire end sleeves are recommended.) 

After stripping the wires, the order of connecting the positive and negative poles can be reversed.

 

When 

using alternating current (AC), the earth must also be connected to the contact marked with a symbol on 

the connector surface: 

 

 
Intended use  

The  connectors  are  only  used  for  connections  between  components,  devices  and  systems,  for  the 

transmission of electrical energy and signals. 

Make sure that the connectors or sockets are always provided with plug contacts on the live side. 
Ensure  that  the  connecting  cables  are  not  subjected  to  unacceptable  tensile,  compressive,  bending  or 

torsional loads. 

Only work with people who meet the specified requirements when working on the connectors. 
Connectors must not be connected or disconnected under electrical voltage. 

Protect the mounting location of the connector from light. 

The use of a flat seal for the electrical connections during assembly is mandatory. 