H Y D R O T E C H P E R F O R M A N C E M O N I T O R
A D VA N C E D F I LT R AT I O N S Y S T E M
w w w. f l u v a l - g . c o m
EN.
34
QUESTIONS & ANSWERS
Q:
How can I remove dust, marks or fingerprints
from the surface of the filter?
A:
ÊÊ1ÃiÊ>ÊÃvÌÊVÌ ÊVÀwLiÀÊÇä¯Ê«ÞiÃÌiÀÊ>`Ê
Ê
ÊÎä¯Ê«Þ>`i®ÊÀÊÌ iÊL>VÊ«ÀÌiVÌÛiÊÃVÊÌ >ÌÊ
wraps the filter. Do not use paper, abrasive
sponges, detergents or alcohol.
Q:
I am not able to start the pump using the
priming
button.
A:
1. Air entering into the intake circuit:
a. Check that the telescopic intake stem and the
intake cross rim assembly are correctly
assembled and the O-rings are correctly
positioned. Disassemble the parts and
reassemble them again by applying a twisting
movement.
b. Check that the hoses are well inserted into the
rim assembly and the ring nuts are properly
tightened.
c. Check that the hoses are well positioned into
the AQUASTOP and the ring nuts are properly
tightened.
d. Check that no dirt is present on the red O-rings
of the AQUASTOP.
2. Check that the AQUASTOP valve is fully open
(valve lever fully down).
3. Check that there are no slacks or loops in the
intake and output hoses.
4. Check that the aquarium water level is not more
than 15 cm below your aquarium rim.
5. Check that the hose connected to the intake
strainer is attached to the correct adaptor of the
Ê
Ê+1-/"*ÊV iVÊÌ >ÌÊÌ iÊÜ>ÌiÀÊyÜÊvÜÃÊÌ iÊ
direction of the arrows marked on the front of
the
AQUASTOP).
ÊÈ°Ê iVÊÌ >ÌÊÌ iÊÜ ÌiÊy>«ÃÊÊÌ iÊÕ`iÀÃ`iÊvÊ
the priming chamber are not blocked by debris
or foreign objects:
a. Remove the mechanical pre-filter cartridge
b. Remove the chemical cartridge
c. Pushing the priming button repeatedly, check
Ê
ÊÌ >ÌÊÌ iÊÌÜÊÜ ÌiÊy>«ÃÊÃ`iÊÌ iÊ«À}Ê
chamber move freely. If this is not the case,
remove the cause of the blockage by means of a
pencil, gently into the openings.
7. Check that the valves of the primer chamber are
still seated properly so they swing freely. In case
they are not, proceed as follows:
a. Remove the mechanical pre-filter cartridge
b. Remove the chemical cartridge
c. By pressing the appropriate ribbed areas,
remove the red valve support.
d. Remove the valves gasket.
e. Position the valves correctly.
f. Re-assemble all parts.
PRIORITY #5 ALERT:
LOW FLOW
The HydroTech system
continuously monitors
Ì iÊÜ>ÌiÀÊyÜÊÀ>ÌiÊ>`Ê
à Õ`Ê>ÞÌ }Ê LÌÊÜ>ÌiÀÊyÜ]ÊÞÕÊÜÊÃiiÊÜÊ
Flow Alert warning.
The Low Flow Alert will appear for several reasons:
Ê UÊ}}i`ÊiV >V>Ê«ÀiwÌiÀÊ>ÀÌÀ`}i°Ê iVÊÌÊ
see that the mechanical pre- filter has been
properly installed and nothing is clogging the
area. See Mechanical Filter Maintenance Section
for more details on cleaning the filter.
Ê UÊ7À}ÞÊÃÌ>i`ÊÀÊÜÀ}ÊwÌÀ>ÌÊi`>°Ê
The filter comes equipped with a filtration media,
but if you choose to use another type of filtering
media, check when it needs to be replaced.
Please refer to the Filter Media section for
further details on how to choose the correct
filter
media.
Ê UÊ-µÕiiâi`ÊÀÊ«V i`Ê Ã}°ÊÊÀ`iÀÊvÀÊÌ iÊ
filter to operate properly, hosing should always
follow a straight path from the filter to the
aquarium rim with some slack but no loops. The
filter will not work efficiently if the hose is too
long or too short. Check that the hoses have
been properly installed.
Summary of Contents for FLUVAL G 3
Page 1: ...USER GUIDE ENTER...