background image

2942 Magnetic Lock

Installation Instructions

I-EA00054

Rev 2, Rev Date: 8/15/18

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

INSTALLATION INSTRUCTIONS

2942 MAGNETIC LOCK

Electrical Instructions:

Use properly fused U. L. Listed Power Supply

Do not install a diode in parallel with any magnetic lock.  A diode

will cause a delay when releasing the door and residual magnetism

to occur.

Although Hager recommends the use of a DC power supply, a

transformer with an adjacent mounted full wave bridge rectifier

may be used.  A significant drop will occur when using a full wave

bridge rectifier.

Any low voltage condition will cause erratic operation of the

optional board sensor.

When using a full wave bridge rectifier all access controls and/or

release contacts must be located between the Magnetic Lock and 

rectifier to ensure quick release.

Electrical Specifications:

Dual Voltage

12 or 24VDC

Power Consumption

500mA@12VDC

250mA@24VDC

DS Door Status Sensor  SPDT, 500mA@30VDC

LS Lock Status Sensor   SPDT, 2A@30VDC

Outswing

Quick Mount

Interlocking

Mounting Assembly

Mounting Screws

Armature

Interlocking

Mounting Plate

Frame

Page 1 of 4