2942 Magnetic Lock
Installation Instructions
I-EA00054
Rev 2, Rev Date: 8/15/18
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
1. Inspect the frame header to determine if mounting accessories are required (refer to page 4).
2. Fold template as indicated on dotted line. For single doors locate template against the door and header
on the lock jamb side of the frame.
3. Mark and drill holes as indicated by the template.
4. Mount armature to door.
STEP 4
STEPS 2 & 3
5. Install magnet onto the header with the magnetic stripes towards the door side of the stop.
Assure that the magnet and armature line up properly, then tighten down ALL mounting screws.
STEP 5
HOLLOW METAL DOOR
From Sexnut side of door, drill exactly 1/2” hole thru one metal
thickness only. From Armature side of door, drill 5/8” hole to insert
reinforcement tube. Press in sexnut and reinforcement tube all the
way and mount armature to door using hardware provided.
REINFORCEMENT
TUBE
1-3/4“
HOLLOW
METAL
DOOR
5/8“ DRILL
STEEL WASHER
2X
RUBBER WASHER
5/16-18 SOC HD
SCREW
WITH 3/16 (5MM)
ALLEN HEX
ARMATURE
1/2” DRILL
SEXNUT
Page 2 of 4