background image

3200 Series ANSI Grade 2 Deadbolt

Installation Instructions

Meets ANSI 156.5

I-LS00764

For use on doors 1-3/8” to 1-3/4” (35 mm - 45 mm) thick

REV 2

Page 1 of 2

1. MARK DOOR

TOOLS REQUIRED FOR NEW 
INSTALLATION:
(1) Phillips Head Screwdriver
(1) 2-1/8” (54 mm) Hole Saw
(1) 1” (25.4 mm) Drill Bit
(1) Chisel

TOOLS REQUIRED FOR 
REPLACEMENT 
INSTALLATION:
(1) Phillips Head Screwdriver

FOR REMODELING OR NEW 
CONSTRUCTION:
-Follow all steps

FOR REPLACEMENT OF 
EXISTING LOCK:
-Follow steps 3C, 4C, and 5 
(single cylinder) or 6 (double 
cylinder) after removal of old 
lock

NOTE: When installing an IC 
Core single cylinder deadbolt 
to a 1-3/8” thick door, you 
must install provided spacer 
ring behind the cylinder 
assembly for proper spacing.

Measure center line of lock; height as 
desired from finished floor.  Select 
2-3/4” or optional 2-3/8” backset, fold 
and apply template to high side of bevel 
door and mark center of door edge as 
indicated on template.  Mark center hole 
on door face through guide on template.

2. DRILL HOLES

Drill 2-1/8” (54 mm) hole through door 
face as marked for deadbolt. (It is 
recommended that holes be drilled from 
both sides on wood doors to prevent 
splitting.)  Drill 1” (25.4 mm) hole in 
center of door edge for latch.

3. INSTALL LATCH

A.  Insert latch in 
hole keeping it 
parallel to face of 
door.  Mark outline 
of latch face plate 
and remove latch.

B.  Chisel 5/32” (4 
mm) deep or until  
latch face plate is 
flush with door 
edge.

C.  Insert latch and 
tighten to the door 
using #8 screws.

4. INSTALL STRIKE

A.  Close door.  Locate strike in jamb and center 
line of strike.  Open door and extend line to door 
stop.  Measure one half of door thickness plus 1/8” 
from door stop.  Vertically mark center line for strike.

B  Drill two 1” (25.4 mm) holes 1-1/4” (32 mm) 
deep in door jamb and 5/16” (8 mm) above and 
5/16” (8 mm) below horizontal center line.  
CAUTION: To ensure proper lockset function, hole in 
jamb must be drilled a full 1-1/4” (32 mm) deep.

C.  Match screw holes on strike with vertical 
centerlines on jamb.  Mark outline of strike and 
chisel 1/4” (6.4 mm) deep for flush fit of dust box, 
wood frame reinforcer, and strike.  Place dust box 
and wood frame reinforcer into mortised area and 
tighten to the frame using 3” wood screws.  Insert 
the strike and tighten to the frame with #8 screws.

NOTE: Mortise 5/64” (2 mm) deep if mounting strike plate only.

MARK FOR 

1” (25.4 mm) 

HOLE IN 

DOOR EDGE

MARK FOR 2-1/8” 

(54 mm) HOLE ON 

DOOR FACE

CENTER LINE

1” (25.4 mm) HOLE

2-1/8” (54 mm) 

HOLE

JAMB

CENTER 

LINE

5/16”

CL

5/16”

CL

KEYS

OUTSIDE CYLINDER

OUTSIDE ROSE

OUTSIDE CYLINDER COLLAR

FIRE/SECURITY SHIELD

MOUNTING 

SCREWS

LATCH

INSIDE CYLINDER COLLAR

INSIDE ROSE

INSIDE CYLINDER

MOUNTING SCREWS

DEADBOLT

STRIKE

WOOD FRAME REINFORCER

STRIKE MOUNTING SCREWS

WOOD SCREWS #10 X 3”

DUST BOX

(ILLUSTRATION: DOUBLE CYLINDER FUNCTION)

Reviews: