I-LS02111
www.hagerco.com
15
Rev 1, 5/16
3.1.13.11.
Activate All User Access Codes
All users may need to be activated if a whole group was deactivated for some
reason, such as a company trip. Use the code below to reactivate all general access
and service user access codes that are not active.
[
*
] [Master or Manager code] [
*
] [33] [
*
] [29] [
*
]
If the setting is successful, then the buzzer will beep once red switching to a
green light. If the setting fails, then the buzzer will beep three times with a
blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or
[#] is pressed to exit immediately.
3.1.13.12.
Deactivate User Access Codes
During events, such as a user’s vacation, user access codes can be deactivated.
Additionally, you might want to create a set of user access codes available to be
assigned in the future which are not currently active.
Use the following code to deactivate user access codes:
[
*
] [Master or Manager code] [
*
] [40] [
*
] [LLL] [
*
]
If the setting is successful, then the buzzer will beep once with a green light. If
the setting fails, then the buzzer will beep three times with a blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or
[#] is pressed to exit immediately.
LLL: User ID; Range 001-500; Type: General Access User
User Access Codes can be continuously deactivated with this function as shown
above in 3.1.13.4. Delete User Access Codes until finished by hitting [#].
3.1.13.13.
Deactivate Manager Access Codes
During events, such as a manager’s vacation, manager access codes can be
deactivated. Additionally, you might want to create a set of manager access codes
available to be assigned in the future which are not currently active.
Use the following code to deactivate manager access codes:
[
*
] [Master code] [
*
] [41] [
*
] [LLL] [
*
]
If the setting is successful, then the buzzer will beep once with a green light. If
the setting fails, then the buzzer will beep three times with a blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or
[#] is pressed to exit immediately.