I-LS02111
www.hagerco.com
16
Rev 1, 5/16
LLL: User ID; Range 001-500; Type: Manager
Manager Access Codes can be continuously deactivated with this function as shown
above in 3.1.13.4. Delete User Access Codes until finished by hitting [#].
3.1.13.14.
Deactivate Service User Access Codes
If for some reason, a service user’s access needs to be suspended for a period of
time; their access codes should be deactivated. Additionally, you might want to
create a set of service user access codes available to be assigned in the future which
are not currently active.
Use the following code to deactivate service user access codes:
[
*
] [Master or Manager code] [
*
] [42] [
*
] [LLL] [
*
]
If the setting is successful, then the buzzer will beep once with a green light. If
the setting fails, then the buzzer will beep three times with a blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or
[#] is pressed to exit immediately.
LLL: User ID; Range 001-500; Type: Service User
Service User Access Codes can be continuously deactivated with this function as
shown above in 3.1.13.4. Delete User Access Codes until finished by hitting [#].
3.1.13.15.
Deactivate All User Access Codes
All users may need to be deactivated for some reason, such as a company trip. Use
the code below to deactivate all regular and service user access codes:
[
*
] [Master or Manager code] [
*
] [43] [
*
] [29] [
*
]
If the setting is successful, then the buzzer will beep once with a red light
switching to green. If the setting fails, then the buzzer will beep three times with
a blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or
[#] is pressed to exit immediately.
3.1.14.
Lockout Mode (Activate / Deactivate )
You many need to use Lockout Mode, for example, during a fire or fire drill when you do not
want anyone to return to their office. This function will deactivate all Access Codes that are
active, including Manager Codes, but excluding the Master Code.
Use the code below to activate or deactivate lockout mode:
[
*
] [Master code] [
*
] [60] [
*
] [P] [
*
]