I-LS02111
www.hagerco.com
7
Rev 1, 5/16
3.1.6.
Setting Passage Mode Active Period (Resets when RTC is
changed, see Section 3.1.15 to activate/deactivate)
You can set a time period where the Passage Mode is active. In Passage Mode, the lock
requires no credentials to gain entry.
Use the code below to set the Start / End times where Passage Mode is active:
[
*
] [Master or Manager code] [
*
] [00] [
*
] [06] [
*
] [hhmmHHMM] [
*
]
If the setting is successful, then the buzzer will beep once with a green light. If the
setting fails, then the buzzer will beep three times with a blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or [#] is
pressed to exit immediately.
hh:
Starting hour to activate Passage Mode; Range 00-23 (24 hour clock)
mm: Starting minute to activate Passage Mode; Range 00-59
HH: Ending hour to deactivate Passage Mode; Range 00-23
MM: Ending minute to deactivate Passage Mode; Range 00-59
E.g.: To activate Passage Mode from 08:00 am to 05:00 pm, enter the following:
[
*
] [Master code] [
*
] [00] [
*
] [06] [
*
] [08001700] [
*
]
If you do not require a certain time period for passage mode, enter 00000000 for the
date code entry.
3.1.7.
Setting Tamper Attempt Limit
This code sets the number of attempts to tamper with the lock before the alarm sounds.
Use the code below to set the number of attempts triggering the alarm:
[
*
] [Master or Manager code] [
*
] [00] [
*
] [07] [
*
] [TT] [
*
]
If the setting is successful, then the buzzer will beep once with a green light. If the
setting fails, then the buzzer will beep three times with a blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or [#] is
pressed to exit immediately.
TT:
Tamper Attempts; Range 00-10; Default is 01
TT=00 deactivates the alarm function
NOTE:
During Passage Mode, ONLY programming functions can be operated. A
green light will flash 3 times as a reminder every time another code is