Interior Door Width

24"

(610mm)

30"

(762mm)

34"

(865mm)

38"

(965mm)

48"

(1219mm)

54"

(1372mm)

Size 2

(5ccw)

Size 3

(0)

Size 4

(5cw)

Size 5

(10cw)

Size 1

(5ccw)

Size 1

(10ccw)

Size 2

(0)

Size 3

(5cw)

Size 4

(10cw)

Exterior (and Vestibule) Door Width

24"

(610mm)

30"

(762mm)

36"

(914mm)

42"

(1067mm)

Size 3

(0)

Size 4

(5cw)

Size 5

(10cw)

Size 3

(5cw)

Size 4

(10cw)

Regular Arm &

Top Jamb

Parallel Arm

Regular Arm &

Top Jamb

Parallel Arm

Minimum Door Width (24")

Minimum Door Width (24")

L

S

L

S

ADJUSTMENTS (USE 5/32" HEX WRENCH FOR THESE ADJUSTMENTS)

SPRING POWER ADJUST  (Sizing in accordance to  BHMA/ANSI 156.4)

ARM PLACEMENT IN SHOE

SWEEP SPEED

LATCH SPEED

BACKCHECK

5200 Series Door Closer - Adjustments

Installation Instructions

Meets ANSI A156.4

6

HAGER COMPANIES

 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995 • Fax (800) 782-0149

(Use 5/32" Hex Wrench 
for this adjustment)

Adjust latch speed so door 
completely closes and latches.

Adjust backcheck accordingly 
to prevent excessive opening 
speed.

Note:

 Adjust closing time speed 

to between 3 and 7 seconds 
from 90˚ to 0˚. Greater closing 
times may be required for 
elderly or handicapped.

TABLE OF SIZES

Closer is shipped set to size 
3. To change the closer size, 
use a hex wrench to rotate 
the spring power adjust. 
Follow the chart to make the 
correct numbers of 360° 
turns to set the closer size 
appropriately for the door 
application.

The number of turns is an 
approximation and does not 
account for environmental or 
door hardware affects.

Approx. 5 turns to 

increase / decrease one size.

cw = clockwise

ccw = counterclockwise

7-1/2% Stronger

7-1/2% Weaker

or

or

-

-

-

-

-

-

-

-

OPTIONAL DELAY ACTION

Adjust delay action accordingly to 
obtain desired delay time.

L

S

ADJUSTMENT DIAGRAM

DELA

Y

Reviews: