18
Attention
Security norms
The knife is very sharp. Do not reach into the cutting area and do not touch the edge
of the knife.
The cutting area is to be kept clean. It’s absolutely necessary that the scrap is removed
from the cutting area. Remove parts, e.g. chips, rejects with suitable and safe tools.
Risk of injury.
The device must be completely mounted on a firm and tilt-proof basis before operating.
The mounting parts are not included. Please use suitable and rugged mounting parts
according to the basis.
For ideal cutting results and operation of the device the knife has always to be sharp. If
dull it has to be exchanged.
The spring-loaded blade guard has to fold up promptly after the cutting procedure. If this
feature does not work the knife has to be secured or removed immediately to avoid inju-
ries. Before operating the device again the blade guard has to be repaired or exchanged.
Specified condition use
The bench mount wiring duct cutting tool VTC125 is only to be used to cut plastic wiring
ducts and covers up to a width of 125 mm and a wall thickness up to 2,5 mm.
It’s only suitable for PVC.
09
!
Messa in servizio
1.
Montaggio
1.1
Fissaggio su un supporto stabile, protetto contro eventuali ribaltamenti (ad es. banco
da lavoro).
Stabilire la posizione e fissare l’apparecchio. Usare il materiale di fissaggio
idoneo. (non in dotazione)