6LE005569B
Product Presentation
The EGN200AU and EGN400AU time switches are
clocks with weekly and annual electronic programming
that automatically control different loads.
Examples of applications: street lighting, neon signs,
shop windows, monuments, facades etc.
The integrated astronomical clock can be set to
switch loads according to sunset and sunrise times.
The connection of an EEN002 / EEN003 twilight
sensor (optional) makes it possible to switch the loads
according to brightness.
Programming by mobile terminal is recommended
via Bluetooth
®
technology by using the configuration
application (iOS and Android) available as a free
download.
Main features
• Product delivered with updated time and day.
• Programming by application via Bluetooth
®
or local
programming (except annual).
• Backlit screen.
• Automatic daylight savings time change.
• Astronomical mode.
• Programming by day or group of days.
• 200 or 400 program steps (depending on version)
On, Off, pulses .
• Permanent overrides On or Off.
• Temporary overrides On or Off.
• Exceptions (temporary, permanent or delayed) can
be activated remotely using a push button.
• Bar graph display of the daily profile for 2 or 4
channels (depending on version).
• Programmable when off via screen only (with limited
functionality).
• Twilight switch function via an EEN002 or EEN003
wired brightness sensor.
Display and keys
Screensaver
▲
▼
Date
Bluetooth
®
enabled
Time
Channel
status
A, B,
C, D
(depending
on version)
Press once to turn backlight on,
twice to display the home screen.
Home screen
0
6
12
18
24
Bar graph
of the daily
profile
Brightness
Time
Display the
manual
controls
screen
(brief press)
Change
the channel
A, B, C or D
(depending on
the version)
Selection of days
(cursor)
LMMJVSD
Channel
currently
displayed
Figure 1:
Presentation of the screensaver and home
screen
Functional features
• Programming capacity: 200 or 400 steps depending
on the model
• Min. time between 2 steps: 1 minute
• Precision of operation: ± 0.25 s / day
• The product switches to the standby state (display
off) after 1 minute of no voltage or inactivity.
It returns to auto mode when power is restored or
when a key is pressed.
• Bluetooth
®
radio frequency: 2.4 - 2.483 GHz
- Max. transmitting power: 10 mW
- Range: 10 m in free field
- Version: 4.2
• Mobile/PC terminal configuration
- iOS version equal to or greater than 8
- Android version equal to or greater than 5.1
- Windows version equal to or greater than 10
- Bluetooth
®
: version equal to or greater than 4.2
• Insulation class: 2
• Action type: 2B
• Software class: Class A
• Ball test T°: 75 °C
• Upstream protection: 16 A circuit breaker
• Stated voltage and current for EMC emissions
testing: 230 V~ / - 0.5 A
• Protection class: IP20 (case), IP30 (case under
faceplate)
• Impact resistance: IK04
Battery
• Power reserve: 10 years with no action
• Non-replaceable and non-rechargeable
Case
• EGN200AU dimensions: 36 mm / 2 modules
• EGN400AU dimensions: 72 mm / 4 modules
• DIN rail mounted independent product according to
EN 60715
Environment
• Operating T° -5 °C to +45 °C
• Storage T° -25 °C to +70 °C
• Relative humidity: 95 % to 20°C
• Pollution category 2
Connection with screw terminals
• Rigid 0.2 to 4 mm
2
• Flexible 0.2 to 2.5 mm
2
• Screw recess: PH1
Initial set-up
With the configuration application
If the application is used to configure the clock, install
as described below.
1.
Directly access the download link of the application
by scanning the
QR code
printed on the clock and
the instructions with a mobile terminal.
2.
Download and install the configuration application.
3.
Check that Bluetooth
®
is enabled (see
Settings /
BLUETOOTH
chapter).
4.
Pair your mobile terminal and your clock via the
Bluetooth
®
application.
5.
Program your product via the application. To do this,
follow the application instructions to configure the
clock.
With the local programming interface
During initial set-up, set the following:
• language;
• year, month, day;
• hour and minutes;
• daylight savings time change.
Press keys
3
/
4
to enter the required settings on the
display.
Press the
ok
key to confirm.
Once the settings are completed, the clock switches
to automatic mode.
Manual commands
From the screen saver, press one of the 4 keys twice
to activate the backlight and then switch to the
home screen. Display the manual controls screen by
pressing the
ok
key.
From the screen saver, press one of the 4 keys twice
to activate the backlight and then switch to the
home screen. Display the manual controls screen by
pressing the
ok
key.
HOME
SCREEN
MANUAL
CONTROLS
HOME
SCREEN
Press a key
twice
All programming and settings are based on the
following principle:
• Keys
3
/
4
are used to navigate between outputs A,
B, C and D (depending on version).
• briefly press the OK key repeatedly to display the
various manual control options for the selected
output.
Connection diagram
• Device to be installed only by a qualified
electrician according to the standards
applicable in the country.
• Before connecting the brightness sensor, or
before carrying out any operations on
it, cut the 230 V power supply to the clock.
1
Override input
or exception
2
Brightness
sensor
Figure 2:
EGN200AU connection diagram (2 outputs)
1
Override input or exception
2
Brightness sensor
Image 3:
EGN400AU connection diagram (4 outputs)
Technical specifications
Electrical specifications
• Supply voltage: 230 V~ +10/-15%
and 240 V~ ± 6%
• Network frequency: 50/60 Hz
• Consumption: EGN200AU < 350 mW / EGN400AU
< 500 mW
• Output 2 or 4 non-insulated changeover contacts
(depending on the version)
• Max. breaking capacity: AC1 μ 16A 230 V~
• Incandescent light bulbs, power relay with contact:
normally open / 2300 W_normally closed / 1500 W
• Halogen lamps: 230 V~ 2300 W
• Fluorescent tubes, compensated // (max. 45 μF),
power relay with contact: normally open / 400 W_
normally closed / 300 W
• Fluorescent tubes, uncompensated, series
compensated: 1000 W
• Compact fluorescent lamps and LED lamps, power
relay with contact: normally open / 400 W_normally
closed / 300 W
• Min. breaking capacity: AC1 100 mA 230 V~
• Rated shock voltage: 4 kV
• Maximum switching speed at full load: 6 switching
cycles/minute
6LE005569B
1
EGN200AU, EGN400AU
Hager Mood
z
Multi-function Time Switch
2 Channel Bluetooth
®
Multi-function Time Switch
4 Channel Bluetooth
®
Additional information
is available by
scanning the displayed
QR code with your
mobile terminal.
Complies with
IMDA Standards
DA101847