Universal Remote Control
Dimmer 500W
EVN002
échelle 100%
EVN002
500
W 45°C
N
L
E1
EVN002
500
W 45°C
N
L
E1
Z
Product description and working
principle
Remote control dimmer EVN002 allows to dim
light of an incandescent load, low voltage LV
halogen (230V), extra-low voltage halogen (12V
or 24V ELV) with electronic or ferromagnetic
transformer, fl uo-compact dimmable light with
built-in supply, dimmable 230V LED lamp with
built-in supply, or very low voltage dimmable LED
lamp (ELV 12V or 24V) with electronic transformer.
This product is a universal dimmer with automatic
load control and built-in teaching feature for more
effi ciently fl uo-compact and 230V LED lamp
adjustment.
Dimming is done by using built-in pushbutton 1 on
the product front face, or pushbuttons connected
to the product.
• Short repeat pressure : to switch light on/off.
• Extended pressure (400ms and up) :
dimming up to the minimum or maximum lighting
level. Adjustment direction (down/up) is reversed
on each new extended pressure action.
Load teaching
Load teaching allows to detect load characteristics
in order to control it more effi ciently.
• Press the pushbutton for 10 seconds until the
load fl ickers once. Upon pressing, the load may
fl ash.
• Press the pushbutton shortly once to start the
teaching procedure. This operation lasts for
about 30 seconds and makes the lighting level
vary.
• After the process has ended, the load switches
on to the maximum level and fl ickers once to
signal teaching completion. Depending on the
connected load, the minimum lighting level can
be modifi ed.
Factory reset (automatic mode)
If a conventional load is installed again, it is
possible to reset the "factory" dimming mode :
extended pressure for 10 s., then 2 short repeat
pressure actions. The product will confi rm factory
reset by making the load fl icker twice.
If no action occurs within 10 s. after extended
pressure, the product will be returned to the
previous dimming mode. This mode is most suited
to the conventional loads.
échelle 1
EVN002
500
W 45°C
N
L1
L2
E1
ε
N
L
1
EVN002
500
W 45°C
N
L1
L2
E1
ε
Connection diagram and visual
product presentation
Installation Instructions
Install the product at the bottom of the enclosure
to prevent excessive operating temperature.
We recommend separating dimmers EVN002 from
high power electromechanical devices (contactors,
circuit breakers).
Protection against overheating or
overloads
In the event of overheating or overload, power
available is automatically reduced.
In order to prevent this from happening :
• adjust or decrease the load connected to
dimmer output,
• decrease temperature of the product and the
enclosure by inserting heat dissipation inserts
(e.g. LZ060) on both sides of dimmer EVN002
and by ensuring adequate ventilation.
In the event of short-circuit or excessive overload,
the load is no longer controlled.
In order to prevent this from happening :
• check whether output is in short-circuit,
• reduce power of the load connected to the
product.
Technical specifi cations
Electric characteristics
• Supply voltage : 230V AC 50/60Hz
• No-load consumption : 0.2W
• Maximum product dissipation : 4.5W
Functional characteristics
Supplied power
• 230V incandescent and halogen lamps : 500W
• ELV 500VA halogen lamps via ferromagnetic
transformer
The transformer shall not be used under
75% of its nominal load.
• ELV halogen and dimmable 500VA ELV LED
lamps via electronic transformer.
The maximum number of lamps allowed shall be
calculated based on transformers output.
• Dimmable fl uo-compact lamps with 230V built-in
ballast : 100W
• 230V dimmable LED lamps : 100W (10 lamps)
Non-dimmable fluo-compact and LED lamps are
not compatible with this product.
Control input
• Voltage : 230V AC 50/60Hz
• Connection distance : 50m
• Unlighted pushbuttons
Environment
• Operating T° : -10 °C to +45 °C
• Storage T° : -25 °C to +70 °C
Connection :
• Flexible capacity : 1.5 mm² - 6 mm²
• Rigid capacity : 1.5 mm² - 6 mm²
Standards
IEC 60669-1; IEC60669-2-1
Usable in all Europe
M
and in Switzerland
For use in Australia and New Zeland
A load shall be connected to perform
the teaching or factory
reset process.