background image

 

Accessories

Technical changes reserved

99

 

6.2.15 

Door frames as spare parts

Door frames for FD…N as spare part

1

2

3

4

Enclosure

height

FD Serie

(193 mm deep)

Reference

ending letters

Top/bottom

plastic part

(2x needed)

Metallic side

part RAL9010

(2x needed)

Extruded

plastic side

part for cover

fixation (2x

needed)

Plastic screw

kit (4 screws

1FD02900

included)

450

22

AN, BN, CN, DN,

GN, LN, MN

1FD02701

1FD05290

5D020100

ZZ42BS

600

32

1FD05390

5D020200

750

42

AN, BN, CN, DN,

GN, LN, MN, BMN

1FD05890

5D020300

900

52

1FD05990

5D020400

1050

62

AN, BN, CN, DN,

GN, LN, MN

1FD10390

5D020500

1200

72

1FD05790

5D020600

4

Door frame fixing plastic screws as spare part

Door frame fixing plastic screws (for surface 

and flush) can be ordered as spare part under 

ZZ42BS ref (BS stands for „Blendrahmen 

Schrauben“)

ZZ42BS

Summary of Contents for New VegaD

Page 1: ...Technical Manual New VegaD for surface mounting flush mounting Accessories...

Page 2: ...ensions 21 4 2 Market specific product ranges 22 4 2 1 DN Version 22 4 2 2 AN Version 23 4 2 3 BN Version 24 4 2 4 CN Version 25 4 2 5 LN Version 26 4 2 6 GN Version 27 4 2 7 RN Version 28 4 2 8 MN Ve...

Page 3: ...4 1 Surface enclosures without door FD N 107 7 4 2 Surface enclosures with door FD N 108 7 4 3 Flush enclosures without door FU N 109 7 4 4 Flush enclosures with door FU N 110 8 Wall fixation 111 8 1...

Page 4: ...lgear assembly Also observe the supplied assembly manual for the respective enclosure or enclosure accessories Store the manuals in a safe place The authorised personnel must have access to the manual...

Page 5: ...nclosed design the New VegaD enclosures are intended for stationary indoor surface and flush mounting in walls hollow walls The operating conditions for the indoor installation according to EN 61439 a...

Page 6: ...istribution boards for operation by ordinary persons according to EN 61439 3 DBO Ordinary persons All other components must be secured against use by ordinary persons Inspection and maintenance Electr...

Page 7: ...ges reserved 7 3 Product range by New VegaD surface 3 1 External dimensions FDX2 BN CN DN LN RN ZN ACN full equipped FDX2 AN MN partly equipped FDX2 BMN partly equipped Multimedia Product range by New...

Page 8: ...About the New VegaD enclosure 8 Technical changes reserved FDX2GN empty FDX2ZN tarif bleu triphas...

Page 9: ...xplanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws Paper cover marking strips 24 mod and holder Cable strain reli...

Page 10: ...expla nation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws Paper cover marking strips 24 mod and holder Cable strain re...

Page 11: ...ck Connect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws Paper cover marking strips 24 mod and holder Drawi...

Page 12: ...4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws Paper cover marking strips 24 mod and holder Drawing map FD42BMN 1x 1x KN06E 1x 1x FD00C4 2x 1x 1x 1x 1x 1x...

Page 13: ...the New VegaD enclosure Technical changes reserved 13 FD00P5 Parts delivered by in each BMN enclosure FZ794 VZ00ASF Example multimedia enclosure FD42BMN left associated with standard enclosure FD42CN...

Page 14: ...Quick Connect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws Paper cover marking strips 24 mod and holder Dr...

Page 15: ...cket surface or flush Instruction sheet w o Quick Connect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws Pap...

Page 16: ...Italy Equipment delivered by PEN QC holder 24 modules wide Instruction sheet with Quick Connect explanation 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixa...

Page 17: ...explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws FD versions only Paper cover marking strips 24 mod and holde...

Page 18: ...sheet with Quick Connect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws Paper cover marking strips 24 mod a...

Page 19: ...phas without door main market France Equipment standard Kit Michaud Platine 330x300 with cover Instruction sheet with Quick Connect explanation 4 screws kit 4x16 for optional PEN holder or slider fixi...

Page 20: ...ruction sheet with Quick Connect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing 5 caps kit for covering wall fixation screws DIN A4 12 mod stripes sticke...

Page 21: ...About the New VegaD enclosure Technical changes reserved 21 4 Product range by New VegaD flush 4 1 External dimensions FUX2LN full equipped FUX2 AN MN partly equipped FUX2GN empty...

Page 22: ...struction sheet with Quick Connect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing Plaster cardboard protection Paper cover marking strips 24 mod and hold...

Page 23: ...explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing Plaster cardboard protection Paper cover marking strips 24 mod and holder Cable strain relief bar FU22AN...

Page 24: ...xplanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing Plaster cardboard protection Paper cover marking strips 24 mod and holder Drawing map FU22BN 1x 1x KN10E 1x...

Page 25: ...t explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing Plaster cardboard protection Paper cover marking strips 24 mod and holder Drawing map FU22CN 1x 1x KN10E...

Page 26: ...able bracket flush Instruction sheet w o Quick Connect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing Plaster cardboard protection Paper cover marking st...

Page 27: ...y Equipment standard PEN QC holder 24 modules wide Instruction sheet with Quick Connect explanation 4 screws kit 4x16 for optional PEN holder or slider fixing Plaster cardboard protection FU22GN 1x 1x...

Page 28: ...onnect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing Plaster cardboard protection Paper cover marking strips 24 mod and holder FU22RN 1x 1x KN10N 1x KN1...

Page 29: ...ck Connect explanation Cover slot strip JP002 4 screws kit 4x16 for optional PEN holder or slider fixing Plaster cardboard protection Paper cover marking strips 24 mod and holder FU22MN 1x 1x KN10N 1x...

Page 30: ...oor material full steel door 1 2mm thick FD22PN 1x FD32PN 1x FD42PN 1x FD52PN 1x FD62PN 1x FD72PN 1x TN Version transparent door Door material Tempered 3mm glass FD22TN 1x FD32TN 1x FD42TN 1x FD52TN 1...

Page 31: ...Doors for flush and surface enclosure Technical changes reserved 31 Standard closing system can be sealed with max 1 5mm wire Standard closing system is available as spare part with reference FD00S0...

Page 32: ...int was heavily criticized by customers speaking about old VegaD flush as the punching out of steel part could have caused damages on frame or injuries In New VegaD surface enclosures customer doesn t...

Page 33: ...Each door is composed of 1 fix hinge and 1 removable one Both hinge positions can be adjusted up to 2mm by hand by turning small wheel arrow so that door fits perfectly into frame Hinges have a small...

Page 34: ...s first 2 letters always FD first number 0 for equipment units accessories and spare parts New VegaD system only second number 0 for simple accessories and spare parts 1 for equipment units 1 row heig...

Page 35: ...Equipment units height 150 mm FD01A1 Kit for 1 distribution DIN rail 430 x 150 x 147 mm with 1x label holder paperstrip 24 modules 4 mounting screws and 2 cable brackets for surface delivered by with...

Page 36: ...paperstrip 24 mod 1 blanking strip 1 5 module 27mm and 4 mounting screws delivered by MCCB H3 or H3 3 or 4 poles 160A to screw in horizontally label holder paperstrip 24 mod to cut out to wished size...

Page 37: ...Accessories Technical changes reserved 37 MCCB fixing on metal plate with M4 screws delivered by...

Page 38: ...N rails 430 x 300 x 147 mm with 2x label holder paperstrip 24 mod 4 mounting screws and 4 cable brackets surface delivered by with 300mm 2x slotted cover 24 mod FD02A2 Kit with 2 depth adjustable DIN...

Page 39: ...x label holder paperstrip 24 mod 2 cable brackets surface 8 mounting screws and 2 DIN rail insulating parts delivered by with 300mm 1x slotted cover 24 mod FD02C2 Kit with depth adjustable perforated...

Page 40: ...premounted screws delivered by with removable 7 mod DIN rail insulation parts with 250 x 250 x 40 mm French Gamma platine premounted FD02F2 Kit with french DB linky meter plate 430 x 300 x 147 mm wit...

Page 41: ...perstrip 24 mod 1 plastic elevation part for modular devices 1 blanking strip 12 mod 2 cable brackets surface and 4 mounting screws delivered by MCCB H3 3 or 4 poles 160A to snap in on DIN rail Kit al...

Page 42: ...Accessories 42 Technical changes reserved...

Page 43: ...poles 250A with add on bloc to screw in horizontally FD02V2 Kit for change over switch 160A 430 x 300 x 147 mm with 1x label holder paperstrip 24 mod 1 blanking strip 24 mod 1 positioning aid metallic...

Page 44: ...mm with 3x label holder paperstrip 24 mod 12 mounting screws and 6 cable brackets surface delivered by with 3x 150mm slotted cover 24 mod FD03Z1 Kit with 3 distribution DIN rails 430 x 450 x 147 mm w...

Page 45: ...older paperstrip 24 mod all 24 mod slotted covers in enclosures and equipment kits are already delivered with 1x label holder paperstrip 24 mod to snap in Reference to use as spare part or to double l...

Page 46: ...epth only 24 mod Partition IP2X to mount in 3 di erent positions Pos 1 direct on uprights no cut out direct use Pos 2 between field with uprights and field modular 1 side to cut out Pos 3 between 2 mo...

Page 47: ...Accessories Technical changes reserved 47 See mounting instruction below...

Page 48: ...Accessories 48 Technical changes reserved...

Page 49: ...kits with 24 mod DIN rails are already delivered with 2 brackets per DIN rail Reference to use as spare part or to complete first two rows in AN or MN versions or to equip GN versions USP Part can be...

Page 50: ...rt cutted out like this Through 20mm raster depth of vertical trunking cover can be adapted to horizontal trunking cover depth as Tehalit trunkings are 60 80 or 100mm high Pos 3 Part can be snapped in...

Page 51: ...vered with 2 brackets per DIN rail Reference to use as spare part or to complete first two rows in AN or MN versions or to equip GN versions Part can be snapped in into 1 single position and loosen th...

Page 52: ...Accessories 52 Technical changes reserved...

Page 53: ...ers can be mounted on all surface and flush enclosures FD00C1 300mm 2x slotted cover 24 mod with 2x label holder paperstrip 24 mod delivered by FD00C2 300mm plain cover 24 mod Inside flat area 430 x 2...

Page 54: ...mod delivered by 2 slots top bottom enable fixing of marking strips FD00A1 FD00C4 150mm 1x slotted cover 24 mod with 1x label holder paperstrip 24 mod delivered by 2 slots top bottom enable fixing of...

Page 55: ...10x13mm 10x22mm deep and 6 mounting screws delivered by 2 plates can be mounted on top of each other within a 3 row empty area 450mm heigth with 10mm spacing for cable through out in between Plate com...

Page 56: ...can be mounted on top of each other 1 each 1 row empty area 150mm heigth with 10mm spacing for cable through out in between Plate compatible with device holder VZ02MM not included FD00M4 140mm plain...

Page 57: ...trical adapter for socket outlet FD00E1 Fixation kit for surface versions Compatible with non exhaustive list 16A socket outlets Push buttons RJ45 USB HDMI Switches Berker cover Integro flow WS100 WS1...

Page 58: ...echnical changes reserved WS032 Not compatible with Berker cover WS035 WS010 Not compatible with Berker cover WS601 LEDs WS264 WS265 WS155 Not compatible with Berker cover 2x WS219 Half modules 2x WS6...

Page 59: ...hanges reserved 59 WS100 WS101 WS106 WS160 Systo products 45mm wide with middle snap only are currently not compatible with Systo adapter excepted 2x half modules WS023T Not compatible WS211 Not compa...

Page 60: ...r available in 10 colours Hager ref WS179 created for France in RAL9010 Standard cover Colour Berker reference Hager reference polar white glossy 918282509 WS179 black glossy 918282510 stainless steel...

Page 61: ...Accessories Technical changes reserved 61 WS100 WS179 WS035 WS179 WS100 9 1828 25 07 WS100 9 1828 25 78 Mounting dismounting 42 43 FD00E1 1 Perforate side opening side with hammer 43...

Page 62: ...ved 47 48 49 44 45 46 2 Stick gasket on adapter 44 3 Snap adapter into enclosure with top inscription on top 45 4 Snap socket outlet with wires into adapter 46 Socket mounting Step Action 1 Put gasket...

Page 63: ...changes reserved 63 Step Action 3 Take care of top side for socket adaptions and snap in adapter into enclosure 4 Fix wires to socket 5 Pass wires into side opening 6 Clip in Socket into adapter See...

Page 64: ...tside or inside and push socket out of enclosure 3 2x Unsnap adapter snaps with heavy finger pressure top bottom or left right hand side See mounting instruction To dismount a socket outlet it is nece...

Page 65: ...6 FD00F Fixation kit FD00F1 Fixation kit for surface versions only to associate 2 surface enclosures vertically to associate 2 surface enclosures horizontally Vertical association first enclosure alr...

Page 66: ...Accessories 66 Technical changes reserved Step Action 1 Perforate holes left right hand side with screwdriver or hammer 22...

Page 67: ...es Technical changes reserved 67 Step Action 2 Insert fixing plates from the top and screw them from the inside with M6 screws 23 3 Cut cable entry plate opening as wished and stick gasket in between...

Page 68: ...4 Insert top enclosure through fixing plates above first enclosure 27 5 Screw them from the inside with M6 screws 27 6 Put insulation caps above all M6 screw heads 27 Horizontal association first encl...

Page 69: ...Accessories Technical changes reserved 69 Step Action 1 Perforate holes top bottom side with screwdriver or hammer 29...

Page 70: ...reserved Step Action 2 Insert fixing plates from the side and screw them from the inside with M6 screws 30 3 Perforate side openings with a hammer and stick gasket around them 31 32 4 Insert side plat...

Page 71: ...ation caps above all M6 screw heads 34 8 Fix second enclosure at the wall with both hands free USP Horizontal association both enclosures on table Vertical association both enclosures on table Same pr...

Page 72: ...cal changes reserved FD00F2 Fixation kit for surface versions only to mount a surface enclosure with 4 external fixing plates Step Action 1 Perforate holes left hand right side and top bottom with scr...

Page 73: ...ng plates from the top and screw them from the inside with M6 screws 38 3 Reinforce stability of assembly by 4x screwing top bottom plastic parts with metallic back panel with 4 small screws delivered...

Page 74: ...essories 74 Technical changes reserved FD00F3 Bar for cables fixation for surface and flush versions to fix incoming outgoing cables with cable straps Part delivered by in each AN and DN surface versi...

Page 75: ...Accessories Technical changes reserved 75...

Page 76: ...th 4 standard mounting screws delivered by Kit to complete with FD00H2 and UZ02B9 FD00H2 2x Top element for DIN rail fixation for surface and flush high depth versions to use as spare part or to compl...

Page 77: ...stic part with 4 screw bag delivered by Fixation screws are the same than for P1 P2 and P3 cable entry plate fixing 4x16mm max Input 80 x 4mm 24 x 25mm Earth Terminal Blocks Description Width Referenc...

Page 78: ...1x brass terminal holder for surface flush high depth and flush low depth versions to complete all versions for K brass terminals mounting Part to screw in on back panel top bottom plastic part with...

Page 79: ...h rectangular openings for surface flush high depth and flush low depth versions Slider included top bottom in each flush version Reference to use as spare part Part can be optionally 2x screwed to ba...

Page 80: ...nges can be ordered as single parts under VZ741 Part can be optionally 2x screwed to back panel top bottom plastic part with 4 screw bag 4x16mm delivered by FD00P3 1x Plate for cable entry Slider with...

Page 81: ...2x Plate for cable entry Side plate for surface versions only USP M40 cable gland head can be screwed directly into side plate winding without its screwing ring M25 cable gland can also be mounted in...

Page 82: ...eight 10K 15K 20K 25K 30K 10K 15K 20K 25K 30K mm mm mm W W W W W W W W W W FD22 450 500 193 Depth installation room 135mm 15 24 8 35 4 46 8 58 7 75 27 15 24 8 35 4 46 8 58 7 75 17 9 29 7 42 4 56 70 2...

Page 83: ...of a water and dust proof round black flange M40 screwed in For Mounting see page 78 Round flange with 6 openings for following cable diameters 1 x 2 0 4 0mm 2 x 3 0 6 0mm 2 x 5 0 9 0mm 1 x 7 5 12 0m...

Page 84: ...flush enclosures after cut out of plastic wall All enclosure back panels can receive 2 flanges for cable back entry top and bottom Reference is also part of slider FD00P2 Flange has been already exis...

Page 85: ...sories Technical changes reserved 85 6 2 10 FD00S Serrure closing system FD00S0 Standard closing system as spare part Mounting Dismounting schema FD00S1 FD00S4 key closing system 1242E 405 Mounting sc...

Page 86: ...Accessories 86 Technical changes reserved FD00S2 FD00S3 FD00S5 special closing system triangle 7mm square 7mm two way 3mm All references are delivered with tool Mounting schema...

Page 87: ...width for horizontal quick fixing between 2 rows without tool delivered with covers BA7A profile basis not compatible with flush low depth as 80mm height would collide with cover Horizontal trunking...

Page 88: ...to be cut from 2m profile to 438mm length by customer Thus it is also possible to clip on smaller BA7A profiles cut to 438mm like 40x30 or 60x30 in flush low depth enclosures See compatibility below...

Page 89: ...gs sideways BA7A and HA7 trunking references shown in table above are compatible with brackets FD00B1 see 6 2 2 and can be mounted vertically in New VegaD surface enclosures Thus it is possible to com...

Page 90: ...FZ Univers cable storage and hiding box In order to hide incoming cables over a New VegaD surface enclosure like FD52 customer can puzzle a wooden based bulky storing box or can order cable storing du...

Page 91: ...Accessories Technical changes reserved 91 FZ142 550mm wide RAL9010 FZ142 550mm wide RAL9010 Cross section 115x155 or 155x115...

Page 92: ...Accessories 92 Technical changes reserved FZ442 550mm wide RAL9010 FZ442 550mm wide RAL9010 Cross section 155x195 or 195x155...

Page 93: ...Accessories Technical changes reserved 93 FZ352 550mm wide RAL7035 FZ352 550mm wide RAL7035 Cross section 155x195 or 195x155...

Page 94: ...Accessories 94 Technical changes reserved Mounting instructions Step Action 1 Choose long side or short side 2 Screw in into wall 3 Clip in front cover 4 Clip in side covers...

Page 95: ...Accessories Technical changes reserved 95 Step Action 5 Ready 6 If needed cut out opening for external vertical cable tray integration...

Page 96: ...Accessories 96 Technical changes reserved Mounting examples FZ142 mounted 155mm vertically FZ352 mounted 155mm vertically FZ442 mounted 195mm vertically FZ352 FZ442 mounted 195mm vertically...

Page 97: ...s DIN rail in each hole with flower shape Part can receive small bracket UZ25V2 surface flush high depth and flush low depth versions or big bracket UZ25V1 surface and flush high depth versions only U...

Page 98: ...Z01V1 Single cover UT50C from cable tray Univers can be snapped on its top to hide cables below Part can be also mounted 180 without adapter under standard Univers DIN rail in each hole with flower sh...

Page 99: ...ixation 2x needed Plastic screw kit 4 screws 1FD02900 included 450 22 AN BN CN DN GN LN MN 1FD02701 1FD05290 5D020100 ZZ42BS 600 32 1FD05390 5D020200 750 42 AN BN CN DN GN LN MN BMN 1FD05890 5D020300...

Page 100: ...ed 537 22 AN GN MN 1FU07301 1FU06190 1FU06700 ZZ42BS 687 32 1FU06290 837 42 1FU06390 987 52 1FU06490 1137 62 1FU06590 1287 72 1FU06690 1 2 3 4 Enclosure height FU Serie with flat frame 40mm overhead R...

Page 101: ...losure height FD or FU size Reference ending letters Vertical upright kit 2 uprights included screw 4 8x25 4x needed 450 537 22 AN BN CN DN GN LN MN RN UN02FN 5E460400 600 687 32 AN BN CN DN GN LN MN...

Page 102: ...ure These springs can be ordered separately if for any reason one is missing with following reference 1 FD or FU size Reference ending letters Fixation kit for vertical uprights 4 counterparts 5G00020...

Page 103: ...pieces hager brand cardboard packaging with 2x white hager labels 175x90mm Equipment units and covers 1 piece hager brand cardboard packaging with 2x white hager labels 85x60mm Single parts plastic ba...

Page 104: ...ective cardboards are made of 2 pieces New vegaD enclosure packagings are very easy to open At shop floor it is also recommended to use the first half for protecting frame or frame with door and the o...

Page 105: ...ons of enclosures Technical changes reserved 105 7 3 Labels 7 3 1 Labels on cardboard packaging Traceability code Enclosures 059 Week 05 Year 9 2019 Equipment units 059 Week 05 Year 9 2019 Doors 4918...

Page 106: ...Packaging and dimensions of enclosures 106 Technical changes reserved 7 3 2 Enclosure type labels Traceability code Enclosures 190291551 Year 19 Day 029 Hour 15 Minute 51...

Page 107: ...190 8 10 6 11 8 630 560 200 FD42DN 750 550 193 8 12 13 2 780 560 200 FD42GN 750 550 193 8 9 2 10 3 630 560 200 FD42LN 750 550 193 8 11 6 12 8 780 560 200 FD42MN 750 550 193 8 10 4 11 6 780 560 200 FD...

Page 108: ...FD32CN 600 550 193 8 14 4 15 8 630 560 200 FD42ACN 750 550 193 8 15 3 17 780 560 200 FD42BMN 600 550 190 8 17 18 2 630 560 200 FD42BN 750 550 193 8 16 2 17 8 630 560 200 FD42CN 750 550 193 8 16 7 18...

Page 109: ...150 10 12 8 14 2 875 645 160 FU42GN 837 600 182 8 11 2 12 6 875 645 192 FU42LN 837 600 150 10 12 6 14 875 645 160 FU42MN 837 600 182 8 12 2 13 6 875 645 192 FU42RN 837 600 150 10 12 8 14 2 875 645 16...

Page 110: ...FU22CN 537 600 150 10 11 1 12 2 575 645 160 FU32BN 687 600 150 10 14 2 15 6 725 645 160 FU32CN 687 600 150 10 14 4 15 8 725 645 160 FU42BN 837 600 150 10 17 3 19 875 645 160 FU42CN 837 600 150 10 17 7...

Page 111: ...2 in the middle to cut punch out to use as pre fixation 4 fixation holes at the edge have been enlarged to ease introduction of screw head and its grommet All FD enclosures are delivered with 5 plast...

Page 112: ...rotection without door is 15mm frame regulation recommended Frame can be regulate until 23mm above back panel flush high depth and more than 35mm by flush low depth For hollow wall fixation the kit VZ...

Page 113: ...can be mounted horizontally or vertically until 30mm wall thickness It is recommended to set back panel on wall edges to support weight before using hollow wall kit to ensure good fixation over years...

Page 114: ...with added opening in back panel For this a line has been designed on plastic part black line on the picture so that the customer can follow it with its cutter and needs only to cut out plastic As for...

Page 115: ...n flush enclosures Each flush enclosure is delivered with a plaster protection cardboard to fix on back panel Cardboard protection is the same for flush low depth and flush high depth but has to be be...

Page 116: ...Wall fixation 116 Technical changes reserved Example of flush low depth enclosure protection against plastering...

Page 117: ...nclosures IP30 without door IP40 with door Indoor and or outdoor installation for indoor installation Datas for air leakage distance Clearance and creepage distances Overvoltage category III Pollution...

Page 118: ...8 6 136 2 50 FD72 1200 28 5 47 1 67 4 89 0 111 6 75 39 3 65 0 93 0 122 7 154 0 50 9 2 2 Power loss for surface enclosures with ventilation openings FD00P5 Enclosure Permissible power loss Pperm for en...

Page 119: ...0 44 7 63 9 84 3 105 8 50 FU72 1286 1200 22 8 37 8 54 1 71 4 89 5 75 30 3 50 2 71 7 94 7 118 8 50 9 2 4 Power loss for standard flush high depth enclosures Enclosure Permissible power loss Pperm for...

Page 120: ...120 Technical changes reserved 9 3 Certifications 9 3 1 VDE certification for Standard DIN EN 61439 1 3 Technical datas certifications...

Page 121: ...Technical changes reserved 121 9 3 2 VDE CB certification for Standard IEC 61439 1 3 Technical datas certifications...

Page 122: ...122 Technical changes reserved 9 3 3 LCIE certification for NF Standard EN 61439 1 3 Technical datas certifications...

Page 123: ...Technical changes reserved 123 9 3 4 VDE certification for Standard DIN EN IEC 62208 for empty enclosures Technical datas certifications...

Page 124: ...FD22PN 30 FU22AN 23 UN05FN 101 5D020500 99 FD22RN 17 FU22BN 24 UN06FN 101 5D020600 99 FD22SN 30 FU22CN 25 UN07FN 101 5E460400 101 FD22TN 30 FU22DN 22 UZ01V1 97 98 BA7A100030 88 89 FD32ACN 17 FU22GN 27...

Page 125: ...ors for flush and surface enclosures 30 E Equipment units 35 Equipment units height 150 mm 35 Equipment units height 300 mm 38 Equipment units height 450 mm 44 F Fixation kit 65 Flush enclosures witho...

Page 126: ...77 S Screws for frame fixing 99 Single and spare parts 45 Storage box for cables 90 Surface enclosures without door FD N 107 T Technical datas 117 Trunking 87 U Univers N cable brackets 97 V Vertical...

Page 127: ...RMANY Tel 49 6842 945 0 Fax 49 6842 945 4625 E Mail info hager de www hager de Hager Support Hager Vertriebsgesellschaft mbH Co KG Zum Gunterstal 66440 BLIESKASTEL GERMANY Tel 49 6842 945 4460 Fax 49...

Reviews: