background image

6LE007714B

01

WBMDUPB

Push-button dimmer

Hager Electro Pty. Ltd., Unit 17/2-8 South Street, RYDALMERE NSW 2116, AUSTRALIA

(2)

(3)

(4)

Fig. 2: Rear view

 The terminal block must be mounted in either 

its original shipped position or on the rear of the 

module by means of the enclosed cable tie.

(1)  Button with status LED
(2)  Retaining lugs for Rotoloc

®

 fastening

(3)  Connection cables
(4)  Terminal block

Function

Correct use

 - Switching and dimming of incandescent lamps, 

HV halogen lamps and dimmable 230 V LED 

lamps; electronic transformers with low voltage 

halogen lamps.

 - Unsuitable for fans and motors
 - Suitable for indoor use only, but no drip and no 

spray water.

 - Suitable for Hager Rotoloc switch plates only

Product characteristics

 -

Phase cut-off dimmer with LED

 -

Wide, infinitely variable dimming range down to 

the lowest brightness for many lamps

 - Programmable minimum brightness
 -

Additional configurable functions

 -

Automatic storage of the switch-off brightness 

level as switch-on brightness level

 - Electronic short circuit, overload and thermal 

protection

 - Multi-way dimming available only with use of 

the WBMSLL slave mechanisms

 - Non volatile device settings

Control

Fig. 3: Push-button dimmer operation

Load 

status

Action

Result

OFF

Short press of 

push-button

Switch 

ON

 with saved 

switch-on brightness 

level.

> 0%

Short press of 

push-button

Switch 

OFF

 and save 

brightness as switch-on 

brightness level.

> 0%

Long press of 

button

With every long push-but-

ton operation within 12 

sec: Dimming with alter-

nating direction, otherwise 

device will dim up, until 

max. level is reached.

Table 1: Push-button dimmer and slave unit operation

Adjusting the minimum brightness

The minimum brightness level can be adjusted with 

the push-button dimmer to prevent poor switch-

on behaviour or flickering of the load in the lower 

dimming range.

 

„

Switch off load.

 

„

Press and hold button for approx 10 seconds.

The lamp and the status LED will flash once 

after 3 seconds and then both flash a second 

time after 10 seconds.

 

„

Release push-button.
The device is now in minimum brightness set-

ting mode. The status LED is flashing fast and 

the load is switched on at minimum brightness.

 Depending on the lamp, the minimum bright-

ness level of the lights installed may be too 

low and the lights may appear off, gradually 

increase the brightness level by repeatedly 

pressing the button.

 If no actions are performed within 10 seconds, 

the dimmer exits programing operation.

 

„

Briefly press the button repeatedly.

The brightness increases gradually.

 

„

Once desired min lighting level is reached, wait 

10 seconds for device to store the setting.

The load will be switched off, the dimmer re

-

turns to normal operation.

 If your minimum setting is set too high, wait 

for the device to exit programming mode and 

repeat the above programming procedure

Configurable additional functions

The additional functions can be configured by 

pressing the push-button dimmer for the required 

number of times.

Kick-start

A short voltage burst when lamp is initially turned 

on to support lamp start-up.

Reduced maximum brightness

A non-adjustble voltage reduction for suppressing 

flickering at maximum brightness.

Status LED

In factory state the status LED lights up only, if the 

lamp is switched on. As described thereunder it 

may be set to be permanently on.

Recovering the previous load state when power 

is restored after a power cut

The status of the load prior to power loss will be 

restored at power-on.

Configuring additional function

 

„

From the off position, press & hold the button 

for approx 10 seconds or more.

The status LED and the lamp will flash once 

after 3 seconds and then both flash a second 

time after 10 seconds.

 

„

Release push-button.
The device is now in minimum brightness set-

ting mode. The status LED is flashing fast and 

the load is switched on at minimum brightness.

 

„

Press and hold the button for 3 seconds until 

the lamp flashes once again and the status LED 

gets off. 

 

„

Release push-button.
The status LED starts blinking fast again.

 

„

Select the additional program function required 

by pressing the button slowly, waiting for the 

load to flash after each press (selected from 

Table 2)  before pressing again.
After approx. 10 s without operation, the change 

of additional function is stored and the device 

switches to standard operation.

Safety instructions

Electrical equipment must only be installed and 

assembled by a qualified electrician in accord

-

ance with the relevant installation standards, 

guidelines, regulations, directives, safety and 

accident prevention regulations of the country.
Failure to comply with these instructions may 

result in damage to the device, fire or other 

hazards.
Hazard due to electric shock. The device is not 

suitable for safe disconnection of the mains 

supply. Even when the device is switched off, 

the load is not isolated from the mains supply.

Do not connect non-dimmable lamps, their 

transformers or operating devices. Observe 

manufacturer's data.
These instructions are an integral component 

of the product and must be retained by the end 

user.

Design and layout of the device

(2)

(1)

(3)

Fig. 1: Front view