0
Installation and Maintenance Manual, Compact CBP
Installation
3.1.4b Mounting the motor onto the driven shaft - splines
Oil to be filled before
tightening G1 plugg
Mounting kit
478 69-801
For flange mounted motors, the spline shall nor-
mally not be subject to radial load.With no radial
load, the splineshaft can be oiled before mounting
the motor. If the motor is subject to radial load, the
splines shall be filled up with oil.
- Mount the motor on to the shaft.
- Bolt the motor to the flange.
- Fill up hydraulic oil to the G1 plug.
- Torque the G1 plug. M
V
=15 Nm/90 lbf
.
ft.
- Mount the cover. M
V
=81 Nm/59 lbf
.
ft for CBP
140, M
v
=15 Nm/91 lbf·ft for CBP 80-840
Oil to be filled before
tightening bolt M0
L=100 mm
Mounting kit
478 69-801
Torquearm mounted motors CBP 140
Motors that carry radial load, must have the
splines oiled. The motor can be used for horizontal
mounting and mounting with motor shaft pointing
downwards.
- Mount the motor on to the shaft.
- Fill up hydraulic oil to the G1 plug.
- Mount washer and bolt.
- Torque the bolt. M
V
=85 Nm/80 lbf
.
ft.
- Mount the cover. M
V
=81 Nm/59 lbt
.
ft.
Flange mounted motors
o-ring
If oil here, it can be used
for the spline. Then take away
the o-ring.
o-ring
10 (0,4) during
filling of oil
Torquearm mounted motors CBP 280-840
Motors that carry radial load, must have the splines
oiled. The motor can be used for horizontal mount-
ing and mounting with motor shaft pointing down-
wards.
- Mount the spacer on the shaft. M
V
=450 Nm/00 lbf
.
ft.
- Mount the motor on to the shaft.
- Fill up hydraulic oil to the G1 plug.
- Mount washer and bolt.
- Torque the bolt. M
V
=85 Nm/80 lbf
.
ft.
- Mount the cover. M
V
=81 Nm/59 lbt
.
ft.