x
V.
OPERATING INFORMATION
TASSELTROL
®
BOTTOM PARAMETER
The bottom parameter is used to adjust the
sensitivity of the bottom photocell. The bottom pho-
tocell stops the down motion when its light is
blocked by corn. How much corn it has to see be-
fore stopping the down move can be changed by
selecting one of the four values B1, B2, B3, or B4.
With B1 selected the down move will stop as soon
as corn is detected. With B4 selected the down
move will continue a little longer. The normal or
default value for this parameter is B1, but can be
set to any desired value.
If the pullers run too shallow after moving down
into shorter corn, increase the parameter toward
T4. If the pullers move too deep when going into
shorter corn or oscillate between the top and bot-
tom photocells, decrease the parameter toward B1.
Generally this parameter can be left at B1.
To display the bottom parameter, select
“AUTO” and turn the control box power on. Wait
three seconds for the “SELECT MANUAL” mes-
sage. Press the “UP” button under ”PAR”. Now
press the “UP” button under the “B” value.
1. The active value of the parameter is indicated
by it blinking on and off, while the other three
choices are displayed continuously.
2. To select a new value for the parameter, press
the “UP” button under the desired choice.
3. After selecting one of the four choices, press
any of the “DOWN” buttons to escape this pa-
rameter.
4. To save new values and escape the parameter
mode, press “DOWN” a second time and
switch “AUTO/MANUAL” toggle to “MANUAL.”
TOP
BOTTOM
PHOTOCELLS
BOTTOM PARAMETER
SET TO B4
BOTTOM PARAMETER
SET TO B1
FIG 5.38
PRESS UP TO SELECT
B1 B2 B3 B4
NOTE:
See page XX for more information re-
garding the LS photolights.