VII.
SERVICE AND MAINTENANCE
J. SPRAY SYSTEM
132
SPRAY TIPS–
At the beginning of each season, or as required, remove a
random sample of spray tip caps (fig. 132-3, item C) and inspect the nozzle tips. If
they are plugged or worn, clean or replace them.
DO NOT
put your mouth to a
spray tip to try to unplug it!
NOZZLE DIAPHRAGMS–
At the beginning of each season, remove each
nozzle body cap (fig. 132-3, item A) and inspect the diaphragm (fig. 132-3, item B)
for wear or fit. Replace if necessary. Refer to accompanying manual containing
nozzle information.
FIG 132-3
B
A
C
SERVICE AND MAINTENANCE