96
V.
SYSTEM PROGRAMMING
HAGIE TASSELTROL
®
CONTINUED
FIG 96-2
1
LIFT
ON
OFF
AUTO
MAN.
DEPTH CONTROL
S. I. E. level 2.1
S. I. E. level 2.1
S. I. E. level 2.1
S. I. E. level 2.1
SELECT MANUAL
SELECT MANUAL
SELECT MANUAL
SELECT MANUAL
CABLE BOX sn: C98ØØ9
CABLE BOX sn: C98ØØ9
CABLE BOX sn: C98ØØ9
CABLE BOX sn: C98ØØ9
PAR=c B1 R2 T3 L6 DØØ
PAR=c B1 R2 T3 L6 DØØ
PAR=c B1 R2 T3 L6 DØØ
PAR=c B1 R2 T3 L6 DØØ
5
LIFT
6
LIFT
2
LIFT
3
LIFT
4
LIFT
Once you have set the operating parameters you
can adjust the response parameters. These parame-
ters are used to adjust the response of the controller
and
SELDOM
need changing. The parameter values
are stored in flash memory and will be retained even
when no battery power is present. Your programmable
control box is factory preset with the following parame-
ter defaults:
BOTTOM PARAMETER – B1
See page 99 to
reprogram the bottom parameter.
RESPONSE PARAMETER – R2
See page 97 to
reprogram the response parameter.
TOP PARAMETER – T3
See page 98 to repro-
gram the top parameter.
These parameters will always be displayed until
the control box is reprogrammed. Once repro-
grammed, the new values for the parameters will ap-
pear in the window of the control box.
To program the unit, first select the response pa-
rameter (page 97). If further adjustment is required for
top and/or bottom parameters, see pages 98 and 99.
SETTING UP THE HAGIE TASSELTROL
®
/LS SYSTEM 12™
LS System 12™ Parameters
FIG 96-1
SYSTEM PROGRAMMING