7-47
SECTION 7 –
SPRAY SYSTEMS
To Drain the Solution Tank
1. Loosen the metal flange clamp and
remove Drain Valve Plug (located on the
end of the Solution Tank Drain Valve
Assembly).
2. Attach an operator-supplied hose to the
end of the Solution Tank Drain Valve
Assembly (where Drain Valve Plug was
previously removed).
3. Turn the Solution Tank Drain Valve in the
OPEN (counter-clockwise) position and
allow solution to drain into an appropri-
ate container for storage.
NOTE: Always ensure that storage
containers and clearly marked with
what type of chemical is being
stored.
4.
When finished draining the solution
tank
, turn the Solution Tank Drain Valve
in the CLOSE (clockwise) position.
5. Remove hose from the Solution Tank
Drain Valve Assembly.
6. Tighten metal flange clamp.
RINSE SYSTEM
Your machine is equipped with a spin ball-
type Rinse System (two rotating rinse balls
located inside of the solution tank) to easily
and effectively rinse the solution tank,
solution pump, and spray booms with fresh
water, which protects against cross-
contamination of chemicals, as well as
reduces the risk of operator exposure. With a
100-gallon (378 L) rinse tank (mounted on
top of the solution tank) full of fresh water,
you may rinse the sprayer out immediately
CAUTION
Wear the appropriate clothing and
Personal Protective Equipment (PPE)
when working with agricultural
chemicals. Do not store chemical-
soaked clothing inside the cab.
NOTICE
When draining large volumes from the
solution tank, it is recommended to
pump off with the solution pump through
the front quick coupler.
Solution Tank Drain Valve Assembly
(Located beneath the solution
tank on underside of machine)
-Typical View
• Drain Valve
Plug
• Metal Flange
Clamp
• Solution
Tank Drain
Valve
Summary of Contents for STS 10