3-51
SECTION 3 –
CAB
To Program the End Row Management
Switch
•
Press the End Row Management Button
to navigate to the “Select Action to Pro-
gram” screen.
•
On the “Select Action to Program”
screen, select the setting in which you
wish to operate the End Row Manage-
ment Switch (located on the Hydrostatic
Drive Control Handle) - “Single Press” or
“Press and Hold”.
•
On the “End Row Management Editor”
screen, press the desired function you
want to set (AWS -
if equipped
, Auto
Steer, Master Spray, NORAC Enable -
if
equipped
, or Return to Height -
120’
Hybrid Booms
).
•
Press the “Delayed Time” cell next to the
function you selected.
•
Press the “+” or “-” Button to adjust to
desired value - amount of time (seconds)
from when the previous action is acti-
vated to when the function is engaged.
•
Press the back arrow when finished.
Total Time
Displays the total time from when the End
Row Management Switch is pressed until the
action is commanded.
Example:
Edit End Row Management Settings
•
On the “Select Action to Program”
screen, press the Settings Button.
•
On the “End Row Management Settings”
screen, use the corresponding slide bar
to adjust value/setting (next to desired
End Row Management setting).
- Pause Before Activate (seconds)
- Display When Active (yes or no)
- Enable Single Press (yes or no)
- Enable Press and Hold (yes or no)
End Row Management Button
(Located on the Main Menu Page)
Select Action to Program Screen
Delayed
Time
Total
Time
Time from when
ERM Button is
pressed to
engagement
1.
0
0
0
2.
0.5
0.5
0.5
3.
1.0
1.5
1.5
4.
0
1.5
1.5
End Row Management Editor Screen
Summary of Contents for STS/DPS Series
Page 2: ...5 DASH AUTO...
Page 5: ...Troubleshooting 10 38...
Page 52: ...SECTION 2 SAFETY AND PRECAUTIONS 2 15 650210 Located on each NORAC sensor...
Page 380: ...NOTES 5 DASH AUTO...
Page 381: ...NOTES 5 DASH AUTO...
Page 382: ...NOTES 5 DASH AUTO...