SECTION 7 –
SPRAY SYSTEMS
7-3
Spray Boom Components
•
(A) - Lift Cylinder
•
(B) - Transom
•
(C) - Main Pivot Cylinder
•
(D) - Level Cylinder
•
(E) - Lift Arm
•
(F) - Main Boom Section
•
(G) - Boom Extension Cylinder
•
(H) - Boom Extension (Outer Fold)
•
(I) - Boom Breakaway Cylinder
Hydraulic Breakaway Circuit
90 and 100-ft. spray booms are equipped
with a Hydraulic Breakaway Circuit. When
folded out as an 80, 90, or 100-ft. spray
boom, a one-way hydraulic circuit (located on
the outer boom section) provides outer boom
breakaway functions.
When the outer boom section breaks
away, it will return to the “spray” position
(after it has cleared the hazard), but will not
be in the locked position.
To Reset the Outer Boom Breakaway
•
Press the Attachment Button (located on
the Machine Display Main Menu Page)
to navigate to the “Boom State” screen.
•
On the “Boom State” screen, press and
hold the Reset Breakaways Button until
the outer boom sections are in the
LOCKED position.
60/80/90’ System with all
Extensions Folded Out
90’
E
C
B
D
A
H
I
G
F
Outer Boom Breakaway
-Typical View
Attachment Button
(Located on the Machine Display
Main Menu Page)