8-3
SECTION 8 –
DPS
Flow Meters (2)
(ARAG® Orion)
The dual Flow Meters (Primary Flow
Meter located beneath the center right-hand
side of machine, and Secondary Flow Meter
located near the front right-hand side of
machine) are an electromagnetic-type with
no internal moving parts, which monitors
solution flow and sends information back to
the spray system console.
NOTE: Flow Meter Usable Range = 3-190
GPM (11.4-719.2 l/min).
NOTE: Flow Meter Calibration = 378 pulses/
per gallon (standard volume system).
Calibration is listed on the flow meter
tag and may vary depending on
options and available equipment.
NOTE:
John Deere and Raven
Controllers:
Flow Meter Calibration
= 3,780 pulses/per 10 gallons.
Pressure Gauges (2)
The Pressure Gauges (located on each
side of the boom - Primary Pressure Gauge
mounted on the right, and Secondary
Pressure Gauge mounted on the left) gives a
constant visual display of solution pressure
being applied (measured in PSI).
NOTE: Pressure will vary according to
speed, application, rate, tip size, etc.
NOTE: The Secondary Pressure Gauge for
Dual Product is equipped with a
second set of wet boom plumbing.
Solution Pump Indicator -
Primary
(Located on the Machine Display
Home Page - Field Mode)
Flow Meter -
Primary
(Located beneath the center
right-hand side of machine)
-Typical View
Flow Meter -
Secondary
(Located near the front
right-hand side of machine)
-Typical View