8-5
SECTION 8 –
DPS
NOTE: Main Tank Valve status is displayed
on the Machine Display Home Page
- Field Mode.
Agitation Valves
(Electrical Actuation and Manual Shutoff)
The flow rate of the Agitation System is
controlled by the Agitation Valve (located
beneath rear of machine) to thoroughly mix
solution in the tank and regulate pressure
and flow to the jet agitators. Increase or
decrease agitation flow by operating the
Agitation Valve Switch (located on the side
console).
A manual Agitation Shutoff Valve (located
beneath rear of machine) is provided to
select tank agitation in either Dual or Single
Product Mode.
•
Dual Product Mode
- Rotate the Agita-
tion Shutoff Valve in the CLOSED (clock-
wise) position to stop agitation of the
front tank (Tank 1).
•
Single Product Mode
- Rotate the Agi-
tation Shutoff Valve in the OPEN
(counter-clockwise) position to allow agi-
tation of the front tank (Tank 1).
Agitation Valve Switch
The Agitation Valve Switch (located on
the side console) is used to increase or
decrease the agitation valve flow rate.
Tank Valve Selector Switch
(Located on the side console)
-Typical View
Main Tank Valve Status Indicator
(Located on the Machine Display
Home Page - Field Mode)
Agitation Valve and Agitation Shutoff Valve
(Located beneath rear of machine)
-Typical View
* Agitation Shutoff Valve shown in the
CLOSED position (Dual Product Mode)
• Agitation
Valve
• Agitation
Shutoff Valve*