Vertex III and Transponder T3 manual v.1.5 eng
© 2007 Haglöf Sweden AB
13
CALIBRATE
Use a measuring tape to measure the exact distance of 10.0 m (32,8 feet)
between the transponder and the Vertex front.
Press ON to start the Vertex instrument. Step in the menu to
CALIBRATE
and
press ON. The instrument will calibrate to 10 m and automatically turn off when
ready.
It is important to give the instrument approximately 10 minutes to set to the
correct temperature before calibrating.
DISPLAY
Set the display contrast for best possible visibility using the arrow keys.
CONTRAST
Start the instrument with ON. Step to CONTRAST and press ON. Change the
contrast with the arrow keys for best possible visibility.
CROSS HAIR SIGHT
Change the light in the cross sight by looking into the sight when measuring and
using arrow keys to increase or decrease the light intensity.
If the sun (back-light) makes it difficult to see, use both eyes when aiming,
and put a finger in front of the sight.
CALIBRATE
DME
23ºC
74ºC
10.00M
CONTRAST
CONTRAST 48