HAGOR Products GmbH | Oberbecksener Straße 97 | D-32547 Bad Oeynhausen | Telefon: +49(0)57 31-7 55 07-0 | Mail: hagor@hagor.de
INSTALLATION AND USE INSTRUCTION
Floor structure videowall
Pag.:
2
BASE POSITION FRONT MOUNTING
BASE POSITION BACK MOUNTING
For the stability of the stucture, the use of ballast is obligatory (see table).
The rules described above are valid for indoor environments with no wind.
If the assembly is done in areas where there may be wind (eg, air
currents, large ventilation)
is necessary to increase the counterweight in an appropriate and / or
anchor the back part of the structure to a solid wall.
2a
2b
M
AX
3
.5
m
M
AX
3
.5
m
Ballast
! ! ! WARNING - DANGER ! ! !
Height (up to) [m]
0.6
1.5
2.15
2.85
3.5
UPPER TO
4.2 [m]
Ballast [kg]
0
40
100
140
220
Contact designer for
specific configuration
BALLAST TABLE