background image

21

Hague Filter Owner's Manual

Water 

Flow

6

9

Drain 

Line 

1”

4

1

3

5

7

8

2

Proper DLFC orientation

directs water flow towards

the washer face with

rounded edge.

DRAIN LINE ASSEMBLY 1”

Item No.

Part No.

Description

Qty.

1

CH4615

 Elbow locking clip

1

2

CV3166

 Drain FTG body 1

1

CV3166-01

 FTG flow control body 1

3

CV3167

 Drain FTG adapter 1

1

4

CV3163

 O-ring 019

1

5

CV3150

 Split ring

1

6

CV3151

 Nut 1" QC

1

7

CV3105

 O-ring 215

8

CV3190-090

 9 .0 gpm DLFC for 1” elbow

One DLFC 

must be 

used if 1" 

fitting is 

used

CV3190-100

 10 .0 gpm DLFC for 1” elbow

CV3190-110

 11 .0 gpm DLFC for 1” elbow

CV3190-130

 13 .0 gpm DLFC for 1” elbow

CV3190-150

 15 .0 gpm DLFC for 1” elbow

CV3190-170

 17 .0 gpm DLFC for 1” elbow

CV3190-200

 20 .0 gpm DLFC for 1” elbow

CV3190-250

 25 .0 gpm DLFC for 1” elbow

9

CV3008-04

 FTG Drain 1" Strt No/Sil

1

Water flow 

Proper DLFC orientation

directs water flow towards

the washer face with

rounded edge.

DRAIN LINE ASSEMBLY 3/4”

Item No.

Part No.

Description

Qty.

1

CH4615

 Elbow locking clip

1

2

CPKP10TS8-BULK

 

Optional 

insert, 5/8” tube

1

3

CV3192

 

Optional 

nut, 3/4” drain elbow

1

4

CV3158-02

 Drain elbow, 3/4” NPT with O-ring

1

5

CV3163

 O-ring 019

1

6

CV3159-01

 DLFC retainer assembly

1

7

CV3162-007

 0 .7 DLFC for 3/4” elbow

1

CV3162-010

 1 .0 DLFC for 3/4” elbow

CV3162-013

 1 .3 DLFC for 3/4” elbow

CV3162-017

 1 .7 DLFC for 3/4” elbow

CV3162-022

 2 .2 DLFC for 3/4” elbow

CV3162-027

 2 .7 DLFC for 3/4” elbow

CV3162-032

 3 .2 DLFC for 3/4” elbow

CV3162-042

 4 .2 DLFC for 3/4” elbow

CV3162-053

 5 .3 DLFC for 3/4” elbow

CV3162-065

 6 .5 DLFC for3/4” elbow

CV3162-075

 7 .5 DLFC for 3/4” elbow

8

CV3331A

 Drain elbow and retainer assembly

    

Items 2 and 3, nut and insert are only used with 1/2” I.D. by 5/8” O.D. 

polytubing. For other piping material, the 3/4” NPT is used.

Replacement Parts

Summary of Contents for HFAIR-1054

Page 1: ...lter Iron and Sulfur Air Draw Filters OWNER S MANUAL AND INSTALLATION GUIDE For Models HFFE 1054 HFFE 1354 HFHS 1054 HFHS 1354 HFAIR 1054 HFAIR 1354 100037741 100037742 100037739 100037740 100037743 1...

Page 2: ...rranty 26 Quick Reference Guide 27 YOUR WATER TEST Hardness______________________ gpg Iron___________________________ ppm pH____________________________ number Nitrates_______________________ ppm Mang...

Page 3: ...and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general operating screen will cycle through...

Page 4: ...er flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Page 5: ...subjected to room temperatures under 33 F 4 Do not subject the tank to any vacuum as this may cause an implosion and could result in leaking If there is a possibility a vacuum could occur please make...

Page 6: ...o a subsurface drainage system or other safe location Remember to follow all local codes When installing the drain line on any backwashing filter especially filters that utilize air as the regenerant...

Page 7: ...is necessary to relieve the pressure from the system Place filter into by pass mode Fig 2 Page 4 and release pressure by manually stepping through an entire regeneration sequence This will adequately...

Page 8: ...REGEN UP DOWN NEXT CLOCK REGEN UP DOWN NEXT CLOCK TIME OF DAY MON GPM 2 40 8 PM Press NEXT to cycle to the next step or REGEN to return to the previous step STEP 1 Press and hold the NEXT and UP butt...

Page 9: ...ing steadily to the drain clear and without the presence of air slowly open the inlet valve Restore power and momentarily press the button to advance the control to the REGENERANT DRAW DOWN position 4...

Page 10: ...is installed GPM flashes on the display when water is being treated indicating gallons per minute flowing through the system 2 REGENERATION MODE Typically a system is set to regenerate at a time of no...

Page 11: ...ERROR appears and flashes alternately with the dealer name and phone number record the ERROR number and contact your servicing dealer promptly This indicates that the control valve was not able to fu...

Page 12: ...TER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are...

Page 13: ...el in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Cont...

Page 14: ...osition or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and...

Page 15: ...GEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP mot...

Page 16: ...losed The alarm buzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or discon...

Page 17: ...o Part No Description Qty 1 CV4381 01 Hague Filter Cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV4377WF WF Replacement Board 1 5 CV3110 Drive gear 12 x 36 3 6 CV310...

Page 18: ...V3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3001 1 body assembly downflow 1 CV3001UP 1 body assembly...

Page 19: ...1 CHECK VALVE ASSEMBLY Item No Part No Description Qty 1 CH4642 WR A Air check valve assembly 1 Although no tools are necessary to assemble or disassemble the valve the Service Wrench shown in variou...

Page 20: ...V3010 1F F injector assembly CV3010 1G G injector assembly CV3010 1H H injector assembly CV3010 1I I injector assembly CV3010 1J J injector assembly CV3010 1K K injector assembly not shown CV3170 O ri...

Page 21: ...08 04 FTG Drain 1 Strt No Sil 1 Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elbow l...

Page 22: ...Part No Description Qty 1 OZ1 A Ozone Kit Assembly 1 2 OZ1 CASE Enclosure Top Bottom and Clip cover not shown 1 3 33217 WRP3 Ozone Cell 1 not shown CJCPG 6PBLK 3 8 Compression Nut 1 not shown CH4642WR...

Page 23: ...OLVENT Item Part No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628...

Page 24: ...24 Hague Filter Owner s Manual This page intentionally left blank...

Page 25: ...1 0 1 0 pH Range 6 8 to 9 0 6 8 to 9 0 Total Dimensions 10 W x 52 H 13 W x 62 H Weight Filled Lbs 106 5 164 Sulfur Filters Iron Air Filters 1 Op onal Ozone Generator not recommended for use on lters...

Page 26: ...d is owned by the original owner This warranty does not cover expendable or misapplied medias or damages due to accident re ood freezing or any other Act of God We are not responsible for damages due...

Page 27: ...DOWN buttons AM PM toggles at 12 3 Press 4 Adjust minutes with UP and DOWN buttons 5 Press 6 Adjust current day with UP and DOWN buttons 7 Press to complete and return to normal operation CURRENT DAY...

Page 28: ...100037746 RevA0120 Iron and Sulfur Air Draw Filter Hague Quality Water Int l 4343 South Hamilton Road Groveport OH 43125 Phone 614 836 2115 Fax 614 836 5349...

Reviews: