background image

OR-05/18/15

Smart Touch Controller Setup Guide

pg.9

Quality Water International 

®

Mode 1 - Timer Mode - Frequency

Mode 1 - Timer Mode - Days of Week

Mode 2 - Demand Delayed Mode

Mode 3 - Demand Immediate Mode

72 - 96 Hour Regeneration

Smart Touch Operating Modes

When the appliance is in Mode 1 - 

Frequency

, it will regenerate based on the frequency that is set.

For example every one day or up to every 20 days. The days between regenerations can be set in the “Service Settings”.

When Frequency is selected, the next 
screen will allow you to chose how 
many days between regenerations.

When Days of Week is selected, the 
regeneration days can be selected in 
the “Customer Settings”.

In “Customer Settings”, check the 
days in which you would like the unit 
to regenerate. “OK” to continue.

Enter the number of days (1-20) 
between regenerations.

When the appliance is in Mode 1 - 

Days of Week

, it will regenerate on a specific day(s) of the week.

When the appliance is in the Patented Savematic Demand Delayed mode, it will regenerate based on the actual water 
usage and the total capacity of the appliance. The time that the regeneration takes place can be set, for example 2:00 
AM. Should the total capacity be depleted before the set regeneration time, a forced regeneration will occur.

When the appliance is in the Demand Immediate mode, it will regenerate based on water usage alone. Regeneration will 
occur when the capacity limit is reached. The time of regeneration cannot be set.

If this value is set to Yes, the appliance will be forced to regenerate every 96 hours unless a regeneration based on water 
usage occurs within the time interval. The value should always be set to Yes if iron is present in the water.

The controller has a Timer mode (Mode 1 Frequency and Mode 1 Days of the Week), a Demand Delayed mode (Mode 
2), and a Demand Immediate mode (Mode 3). These modes are equipped with Capacity Guard

®

, which ensures that a 

supply of conditioned water will be available even with excessive water usage. 

Operating Modes

Summary of Contents for ST-200

Page 1: ...Quality Water International Smart Touch Controller Setup Guide Version 1 0 ...

Page 2: ...ller Setup Guide OR 05 18 15 Quality Water International Table of Contents Smart Touch Controller 3 Setting The Touch Screen Controller 3 Service Settings 4 7 Service Settings History 6 7 Customer Settings 8 Operating Modes 9 ...

Page 3: ...te Ensure that the bottom of the controller is firmly locked onto the four tabs on the top of the drive end cap assembly Figure 3 Smart Touch Controller Customer Settings Gallons Remaining Message Status Indicator Regenerate Service Settings Water Flow Indicator 1 OK Button Press after information is added and move to next screen 2 Back Button Navigates to the previous screen 3 Clr Button Resets a...

Page 4: ...ry Option to show history Yes or No see History in next section OK to continue Language Select the desired language English Français Español Deutsch Italiano OK to continue Total Regenerations Displays number of regenerations For Reference Only Value does reset OK to continue Total Gallons Displays number of gallons that has passed through the unit For Reference Only Value does reset OK to continu...

Page 5: ...ty number 52 to 9999 Grains or 788 to 6999 gm OK to continue Backwash 2 Minutes Second backwash cycle duration Preset 005 0 0 to 999 9 OK to continue Salt Select Regenerant Sodium or Potassium OK to continue Backwash 1 Minutes First backwash cycle duration Preset 001 0 0 to 999 9 OK to continue Salt lbs Amount of salt for each regeneration Preset 006 2 1 0 to 80 0 lbs 0 45 36 99 kg OK to continue ...

Page 6: ...0000 to 999999 OK to continue H Number of People Enter number of people in the household 1 to 50 OK to continue H Software V Software version number For Reference Only OK to continue Service Settings History History is an optional set of menus that acts as a clipboard for storing the history of water chemistry total regenerations amount of water to pass through the unit unit model number and other...

Page 7: ...0 to 99 ppm mg L OK to continue H Total Regenerations Displays number of regenerations Value does not reset For Reference Only OK to continue H Save History Choose to save history Yes or No OK to continue H Manganese ppm Enter Manganese test results 0 to 99 ppm mg L OK to continue H pH ppm Enter pH test results 0 to 99 9 OK to continue H Total Gallons Number of gallons that has passed through the ...

Page 8: ...Tap AP for AM PM hh mm OK to continue Regeneration Time Mode 1 Days of Week Only see Operating Modes section OK to continue People Enter number of people in the household 1 to 50 OK to continue Customer Settings To program Customer Settings on the controller tap twice on the screen to bring up the Main Menu Follow the following steps to set the Smart Touch controller in the Customer Settings Main ...

Page 9: ... day s of the week When the appliance is in the Patented Savematic Demand Delayed mode it will regenerate based on the actual water usage and the total capacity of the appliance The time that the regeneration takes place can be set for example 2 00 AM Should the total capacity be depleted before the set regeneration time a forced regeneration will occur When the appliance is in the Demand Immediat...

Page 10: ...pg 10 Smart Touch Controller Setup Guide OR 05 18 15 Quality Water International Notes Notes ...

Page 11: ...OR 05 18 15 Smart Touch Controller Setup Guide pg 11 Quality Water International Notes Notes ...

Page 12: ...Quality Water International USA Made In Hague Quality Water International 4343 S Hamilton Road 614 836 2115 Groveport OH 43125 www haguewater com 2015 54115 Version 1 0 OR 05 18 15 ...

Reviews: