17
7.3.
Check the oil level
It is important to always check the oil level in the crankcase before use.
To check the oil level:
1.
Make sure the generator is turned off and is standing on a level surface.
2.
Unscrew the cap / bayonet.
3.
Wipe the dipstick with a dry cloth.
4.
Insert the dipstick inward (do not twist), then remove. The oil should be
on the dipstick. If there is no oil on the dipstick or it is at the very end of
the dipstick, refill with oil.
7.4.
Change \ Topping up the oil
To drain the oil:
1.
Place a container below the generator to drain oil.
2.
Remove the oil drain plug located below the crankcase.
3.
Let the oil flow from the generator into the prepared container.
4.
Close the oil outlet with the drain plug.
Never throw used oil into the garbage can or pour it on the
ground. Discard the oil into an appropriate container. If in doubt,
contact the recipient of the waste.
Recommended oil: SAE 15W-40
To top up the oil:
1.
Make sure the generator is on level ground
2.
Remove the oil filler cap
3.
Using a funnel, add the correct amount of oil to the box. The oil should
reach up to the lower edge of the oil filler neck.