10
3. Before starting
For your safety and to ensure the longest possible service life of the
generator, it is important to take a few moments to check the general
condition of the generator. Make sure that every, even minor, fault is
removed before starting it. If there is a problem not described in this
manual, contact the Hahn & Sohn GmbH.
Improper service of the unit and neglect of faults can cause the unit to malfunction,
which can lead to accidents and damage to the unit. Always perform a visual inspection
before each start-up.
Check the general appearance of the generator
-
Check the bottom of the generator and the area underneath for signs of oil
or fuel leakage.
-
Remove excessive dirt.
-
Check that there are no signs of damage.
-
Check that all covers and covers are correctly fitted.
-
Check that all screws are in place and tightened.
Oil level control
To check the oil level in the engine:
1.
Remove the oil filler cap and wipe the dipstick clean.
2.
Put the indicator on the motor (without screwing in).
3.
Remove the dipstick and check the oil level. If the oil level is too low, top up
the oil to the correct level with the correct oil (details on page 18)
indicator /
filler cap
oil
Starting the generator with the wrong oil may shorten the life of the engine or cause
serious damage to the engine, which is not covered by the warranty.
When changing the oil, also replace the oil filter (if present).
Summary of Contents for HDE14000SA-SA3