Installation

Overview

•  Pencil
•  Masking Tape
•  Pan or Bucket

HOT

A

B

D

G

C

E

F

 

G

H

L

T

V

W

X

J

O

COLD

Plan for Installation

Prior to installation, we recommend you read the entire manual to familiarize yourself with 
the system, and help you determine the best location for installation. Please check and 
comply with all local plumbing codes. 

Note: Keep these instructions for future reference.

Prepare Site for Installation

NOTE: If you have metal drain pipes, consult a plumber for installation of drain connection.

•  Prior to installation, close the cold water shut-off valve.

•   Temporarily place system manifold, remineralizer, and 

tank into the under sink cabinet or desired location to 

ensure adequate space and proper positioning. 

•   3/8" white tubing will be used to connect manifold to tank, and from faucet stem to 

remineralizer. Measure out 3/8" white tubing from the top of the tank to the outlet side 
of the system manifold and mark 3/8" tubing. Then measure remaining length of 3/8" 
tubing from the remineralizer to the desired location of the faucet hole to ensure there 
will be enough 3/8" tubing available for both connections. Wait to cut tubing and follow 
instructions below.

•   Remove system, remineralizer, and tank from under your sink to begin installation.

Step 1:

   Install Brass Tee Fitting

Step 2:

   Install RO System Manifold

Step 3:

   Install Water Storage Tank

Step 4:

   Install RO Faucet

Step 5:

   Install RO Drain Connector

Step 6:

   Connect Tubing

Step 7:

   Stage 1–3 Filter Installation

Step 8:

    Sanitize, Pressure Test, 

Purge System

Summary of Contents for AquaH20 HF-RO

Page 1: ...AquaH20 Drinking Water System Owner s Manual MODEL HF RO...

Page 2: ...out G RO Faucet Body Stem stem not shown H Water Storage Tank I Eye Dropper J Tank Connector K Teflon Tape L Drain Connector M Nuts Bolts N Foam Seal O O Ring Faucet Base P Toggle Bolts Q Flow Restric...

Page 3: ...o ensure adequate space and proper positioning 3 8 white tubing will be used to connect manifold to tank and from faucet stem to remineralizer Measure out 3 8 white tubing from the top of the tank to...

Page 4: ...e tube in place tighten the compression nut to compress the plastic sleeve and create a seal NOTE Use a wrench to ensure complete seal Avoid over tightening 5 Do not connect the other end at this time...

Page 5: ...e tubing through the nut collar and sleeve into the connector B Unscrew the compression nut from the tank connector to ensure that the tubing is connected all the way through the collar and sleeve C S...

Page 6: ...k hole until faucet base is flush with countertop Position toggle bolts under sink surface being certain faucet stem will not be obstructed Loosely fasten faucet base to countertop by tightening toggl...

Page 7: ...ocation 2 Remove protective cover from back of foam seal 3 Knock center hole out align holes and attach to front plate of drain connector 4 Allowing room for drilling position the drain connector on s...

Page 8: ...ing in order to prevent crimping kinks loops or folds TUBING DONT S DO NOT cut tubing too short Always double check measurements before cutting DO NOT bend or crimp or kink tubing DO NOT discard exces...

Page 9: ...lled in step 4 from the faucet into the remineralizer port labeled OUTLET IV Manifold to Tank 3 8 white tubing already attached to tank 1 Take the white tubing leading from the storage tank and insert...

Page 10: ...ttach red carbon sump to the 1st stage position on the inlet side of the system manifold Make sure all con nection points are aligned and push the top of the sump up and into the system manifold Turn...

Page 11: ...System 2 To purge air from the plumbing system open kitchen faucet Close faucet when water runs smooth 3 Confirm RO faucet is closed 4 Within approximately 2 hours pressure will start to build in the...

Page 12: ...conditions on the above are 250 ppm TDS and a 30 6 recovery rate Production rate and TDS reduction figures are for a new Membrane that has been rinsed for 24 hours The production rate of a new Membran...

Page 13: ...rapidly convert trivalent arsenic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined c...

Page 14: ...igher than 8 0 membrane life may be as short as 12 months If pH is under 7 5 membrane life may last up to 36 months When output water quality and production rate decrease it is time to replace the fil...

Page 15: ...It is recommended the restrictor assembly be periodically inspected to be sure it is clean and unrestricted If service is required on the drain flow assembly disassemble and reassemble as outlined in...

Page 16: ...ternational against NSF ANSI Standards 42 and 53 in model HF RO for the reduction claims specified on the Performance Data Sheet as verified and substantiated by test data and at nsf org The HF RO sys...

Reviews: