FORMAT NUMBER
DESCRIPTION
STANDARD
0
Preset Dim Command (X-10, X-10 Pro, Leviton, PCS, etc.)
EXTENDED
1
Extended Code Level Command (Leviton)
COMPOSE
2
Compose
Mode
(Lightolier's
Compose)
UPB
3
Universal
Powerline
Bus
(open
format)
RADIO
RA
4
Lutron
RadioRA
HAI
LIGHTING
5
HAI
Lighting
Control
(HLC)
CENTRALITE
6
CentraLite
Lighting
The default setting for HC 1 Format is 5 (HLC).
House Code All Off
This feature allows you to choose if the House Code will respond to the “All Off” command. Press the 0 key to select No and the
1 key to select Yes.
HC 1 ALL OFF: 1
0=NO 1=YES
The default setting for
HC 1 All Off
is Yes.
Notes:
1.
When configured, the House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL OFF affects Room 1 and 2).
2.
When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All Off” does not affect the state of the
installed devices; however, if this setup item is set to “Yes”, OmniLT will change the status of all units on that House Code
to “Off” (even though it doesn’t explicitly send an All Off command to those units). If the “House Code All Off” setup item
is set to “No”, OmniLT will not change the status of units on that House Code.
House Codes All On
This feature allows you to choose if the House Code will respond to the “All On” command. Press the 0 key to select No and the
1 key to select Yes.
HC 1 ALL ON: 1
0=NO 1=YES
The default setting for
HC 1 All On
is Yes.
Notes:
1.
When configured, the House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL ON affects Room 1 and 2).
2.
When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All On” does not affect the state of the
installed devices; however, if this setup item is set to “Yes”, OmniLT will change the status of all units on that House Code
to “On” (even though it doesn’t explicitly send an All On command to those units). If the “House Code All On” setup item is
set to “No”, OmniLT will not change the status of units on that House Code.
Time Clocks
There are three time clocks in the system are used to conditionalize programs. They are used solely to define time periods during
the week when certain programs should be enabled or disabled to execute.
TIME CLOCK 1 ON
TIME CLOCK 1 OFF
Specify the On and Off times for each Time Clock -
See
Set Up Codes.
TIME CLOCK 1 ON TIME:
64