background image

What To Do When You Come Home 

 
Entry through a door: 
 

If you enter your home while the system is armed in the Day or Away modes, using your normal entry door:

 

 

• 

Console beeper comes on - display indicates:  " *** DISARM SYSTEM ***  - PRESS OFF THEN CODE" 

 

• 

Any lights or control modules programmed to come on for the door that you used will do so. 

 

• 

The system will wait the Entry Delay time. 

 
You should go to your console (or telephone) immediately and turn the security system off.  If you wish, you may go directly to a 
different security mode, rather than turning the system Off. 
 
If you return home and hear the alarm sounding or the outdoor lights are flashing, 

DO NOT ENTER

.  Use a neighbor's phone to 

call for help. 
 

What Happens When the Alarm is Activated 

 

Burglar Alarm Activated 

 
If someone enters through any zone other than an 

Entry

-Exit zone, if the security system is in the 

Night

 mode, or if the security 

system is not turned off during the 

Entry

 Delay:

 

 

• 

The sounder is activated, which makes a loud, continuous sound. 

 

• 

The display shows the type of alarm and the zones that have been tripped:   
"BURGLAR ALARM!  -  ZONE NAME TRIPPED". 

 
If more than one zone is tripped, then the bottom line will show each zone tripped for two seconds. 
  

• 

The When Alarm macro is activated.  Any units programmed to come on will do so. 

 

• 

The Flash For Alarm Unit Number begins to flash on and off. 

 

• 

The system now waits the Dial Out Delay.  (0 - 60 seconds) 

 

• 

If programmed, the in-house phones are seized (disconnected) and the Aegis 1000 begins to dial out. 

 
If you are having your system monitored by a central station, the central station will be sent a code representing the type of alarm 
(burglary) and zone involved.  In most cases, the central station will call back, requesting your password or passcode. 
 
If you are not using central station monitoring but are using the voice dial out capability, the system looks at the Dial Order to 
determine which number to call first, and calls that number. 
 
If you are using both central station monitoring and voice dial out, then the voice dial out is delayed by five minutes to give the 
central station time to call you back.   
 
For more information on the digital and voice dialer - 

See

 

Digital Dialer 

and 

Voice Dialer

 

• 

The system continues to sound all alarms and flash the flashing light for 1-30 minutes after the alarm is activated. 

 

• 

After a 1-30 minute period, the sounder is turned off, and the alarm system resets itself.  The console beeper stays on.  
If a zone is tripped after a reset, the sounder will again be activated, and the dialer will again dial out. 

 
At any time, the alarm system can be turned off at the console. 

Summary of Contents for AEGIS 1000

Page 1: ...AEGIS 1000 Owner s Manual Part No AEG1000 OMAN Document Number 21R00 14 Rev A January 2002...

Page 2: ...Copyright 2002 HAI All Rights Reserved Home Systems Plus www aegishome com...

Page 3: ...13 User Code 13 Duress Code 13 Panic Switches 13 Testing Your System 13 CONTROL 14 ALC Switch Modules 14 ALC Module Types 14 X 10 Modules 14 House Codes 14 Unit Numbers 15 Scrolling Through Names 15 C...

Page 4: ...All Off Commands 47 Program Temperature Commands 47 Program Energy Cost 47 Program Message Commands 47 Edit Program Condition 47 Program Control Conditions 47 Program Security Mode Conditions 48 Progr...

Page 5: ...the event that there are any questions please call your installer first If you need assistance directly from the manufacturer call us at 800 401 4663 between the hours of 9 00 AM and 5 00 PM Eastern...

Page 6: ...to arm the security system in the Day mode In the Day mode the perimeter zones doors and windows are protected however the interior zones are not armed so that you may move about freely inside In thi...

Page 7: ...d restoring zones In some cases the keys 0 9 are assigned to different functions From the top level display each key functions as a menu choice 12 CONSOLE BEEPER The Console Beeper is used to confirm...

Page 8: ...Menu The main menu is entered from the top level display by pressing the key This menu displays all of the functions that you can perform from the console It is not necessary to display the main menu...

Page 9: ...normal top level display Aegis 1000 Maintenance Your Aegis 1000 controller and the consoles are designed to require very little maintenance For smoke detectors motion detectors and other components n...

Page 10: ...code again Practice disarming your system until you are comfortable with this procedure NOTES Panic Tamper and Fire zones are always armed as are the Emergency buttons on the console In the event that...

Page 11: ...ame as Day mode however there is no Entry Delay on any of the security zones There will be an instant alarm if any of the zones are violated while in this mode 6 NIGHT DLY NIGHT DELAY Functions same a...

Page 12: ...now read ZONE NAME BYPASSED to remind you that the zone is bypassed If a fire zone is bypassed the console will continue to beep until that zone is restored See Restoring Zones Auto Bypass In order to...

Page 13: ...conds The When Alarm macro is activated Any units programmed to come on will do so The Flash For Alarm Unit Number begins to flash on and off The system now waits the Dial Out Delay 0 60 seconds If pr...

Page 14: ...gas alarm is activated the alarm responds exactly as described under Burglar Alarm Activated except The console display reads GAS ALARM ZONE NAME TRIPPED The sounder will pulse on off on then an exte...

Page 15: ...for a description of when to use In the event that you enter your duress code or a Duress zone is tripped the system performs a silent dial out as follows No alarms lights or console beepers are acti...

Page 16: ...to see that the socket has power check the MAIN fuse F3 on the Aegis BATTERY LOW TRBL NOW or HAD TRBL battery voltage is too low then the console will indicate BATTERY LOW If this happens make sure t...

Page 17: ...and 3 keys simultaneously Press OFF and enter your Code to cancel the alarm and silence the siren 2 To test the security zones you will need a partner to walk around your home and open and close all...

Page 18: ...n pre wired for installation of ALC system products Aegis 1000 controls lights and appliances by sending commands over the ALC signal wiring to ALC Switch Modules ALC Switches communicate with the Aeg...

Page 19: ...tputs 1 and 2 Fully Configurable 29 36 Internal Flags If Aegis 1000 Expansion Module is used Scrolling Through Names The Aegis 1000 stores names for Units Zones Buttons Codes and Temperatures so that...

Page 20: ...NAME unit name being the description of the unit number and the bottom line will read STEPS DIMMER 1 9 Porch Light 9 Pres 9 to indicate how much you want to dim the unit 1 is a little dimmer 9 is a lo...

Page 21: ...17 The rate specifies the time it takes the switch to go from full off to full on or from full on to full off Thus a level change from full off to 50 on will take half the time specified...

Page 22: ...rned on or off for a specified period of time The unit may be turned On for 1 99 minutes or seconds or 1 18 hours then Off or turned Off for 1 99 minutes or seconds or 1 18 hours then On X 10 units 1...

Page 23: ...itions if it is nonzero 1 255 Flags can be turned Off On Decremented DEC Incremented INC Set and Timed ON OFF Controlling Outputs The Aegis 1000 has 2 expandable to 10 outputs that can be used to swit...

Page 24: ...X X X 13 X X X X 14 X X X X 15 X X X X UNIT NUMBERS 16 X X X X X Corresponds to the unit numbers in a Scene Scene Commands Scene Commands are used to Set Scenes issue a Scene On command and issue a S...

Page 25: ...lifestyle Using a button you can activate several commands at once You can personalize 16 buttons with descriptive names Following Button 1 turn off all lights arm the security system in the Away mode...

Page 26: ...d You will be prompted with the first named temperature zone i e Upstairs The temperature zone can be specified by entering the temperature zone number followed by the key or by pressing the arrow key...

Page 27: ...n hold mode on and off For a heat cool thermostat the menu displayed is Upstairs HOLD 0 OFF 1 ON Turn hold mode Off or On by selecting 0 OFF or 1 ON respectively For a heat cool thermostat the status...

Page 28: ...et heating setpoint Set cooling setpoint You can turn the energy saver on off use a timed on off and change the Heat and Cool temperatures from the console or by telephone Commands can also be program...

Page 29: ...1 99 H M S Downstairs FOR 15M 0 OFF 1 ON The current status of a temperature zone may be displayed by selecting STAT key from the main temperature menu The status display differs depending on the temp...

Page 30: ...For example the ceiling fan can be programmed to come on if the temperature goes above the High temperature a programming example to set this up is shown in the Programming section High and Low setpo...

Page 31: ...me of sunrise and sunset each day From the status menu press the 3 SUN key on the console keypad to display the calculated time of sunrise sunset and the outdoor temperature if outdoor temp sensor ins...

Page 32: ...when the system was new wiring problems that will eventually lead to trouble or false alarms may be developing You may wish to record the Status Test values for future reference 5 TEMP TEMPERATURE Th...

Page 33: ...and date on the top line and a description of the event on the bottom line 7 15 PM 5 8 USER NAME AWAY For trouble conditions the event log will show the zone name or specific trouble condition and TRO...

Page 34: ...it is manually cleared or cleared by a program Log Message The 2 LOG key allows you to store the selected text message s in the Event Log This can be a helpful way to keep track of the times and dates...

Page 35: ...ine feed characters are not automatically appended to the end To send ASCII control as part of the message use the caret character in the message This character specifics that the next character is to...

Page 36: ...SWITCH 7 respectively Pushbuttons 1 through 7 on scene switch 1 are mapped to SWITCH 9 through SWITCH 15 and so on Thus eight switch press event buttons are allocated to each scene switch although onl...

Page 37: ...when the Aegis 1000 picks up or hangs up This is normal To access your Aegis 1000 from an in house phone Pick up the receiver of any Touch Tone phone in your house Pause for just a moment about a sec...

Page 38: ...RATURE 6 STATUS 7 EVENT 8 PHONE 9 GOOD BYE CANCEL 0 REPEAT This means that you press 1 for Control functions 2 for Security 3 for Button etc Pressing one of the keys on the phone will move you to anot...

Page 39: ...ode Panic Button over the Phone On an in house phone only you can activate the Police Emergency keys by picking up the phone and pressing the key 6 times This activates the sounder immediately The fir...

Page 40: ...e premises If a Two Way Audio Module is being used after the transmission of the alarm to the central station the operator can talk and listen to people and sounds at the premises If the digital commu...

Page 41: ...it stops talking If you enter the correct Master or Manager code you will then be logged in a remote phone access is logged in the event log and further dial outs are canceled You will hear the statu...

Page 42: ...from the Setup menu press the 1 CODES key Use the arrow keys to scroll through the codes User Code 1 is always set to a Master code The existing code number is not shown on the display To change the c...

Page 43: ...sound no lights will flash but the Aegis 1000 will perform a silent dial out and say that this is a silent alarm To stop a silent dial out turn your security system off by pressing OFF then your code...

Page 44: ...to the Edit Program menu to cancel entry of the new program and return to the Set Up Programs menu Once the new program is entered the display will return to the Set Up Programs menu 2 Show Programs T...

Page 45: ...e program to be changed See Edit Program Edit each part of the program as specified under Edit Program Press the key at the Edit Program menu to show the newly edited program Press the key again to sa...

Page 46: ...ATE DAY Select 1 TIME to enter the new time If the desired time is the time in which sunrise or sunset will occur press the up arrow key for sunrise or the down arrow key for sunset before entering a...

Page 47: ...1 CTRL key allows you to select the event button for a control unit activated event You are first prompted to enter the desired unit number UNIT ENTER UNIT The unit may be entered by entering the unit...

Page 48: ...the mode is prefixed by A for arming into WHEN AWAY END OF DELAY WHEN A AWY START OF DELAY When the system is armed in the Day instant or Night delay mode buttons for the Day and Night modes are execu...

Page 49: ...o Aegis 1000 Aegis 1000 can also respond to scene changes initiated at Compose keypads and dimmers When a scene change is initiated Aegis 1000 can activate an event button program You are first prompt...

Page 50: ...Edit Program menu Program Control Commands Press the 1 CONTROL key to command lights and appliances Specify the desired command See Control Porch Light Unit Name 0 OFF 1 ON 2 DIM 3 BRT Porch Light Un...

Page 51: ...and temperature sensors Specify the desired temperature command See Temperature Program Energy Cost Select the 6 ENERGY key to command the energy cost rate Specify the desired energy cost rate ENERGY...

Page 52: ...cute if a specified security zone is either Secure or Not Ready The display prompts you for the zone number ZONE ENTER ZONE Enter the zone number followed by the key or use the arrow keys to select th...

Page 53: ...ows you to turn the local in house and remote telephone control feature on and off If set to On the Aegis 1000 will allow local and remote telephone access as described in Telephone Control If set to...

Page 54: ...are stored in the system In the event of an alarm these numbers are dialed in the order that is set up in the Dial Out Order for the particular type of alarm Dial out numbers 1 8 have On and Off time...

Page 55: ...51 NEVER CHNG...

Page 56: ...spectively When you have entered the dial order of your choice press Enter a single 0 if no dial out is desired The default Dial Order is 1 2 3 4 5 6 7 8 Set Up Arming To configure different arming an...

Page 57: ...cally bypass an open zone when the system is armed rather than setting off the alarm In some applications it may be preferable to allow arming only if all zones are secure READY With Auto Bypass Off a...

Page 58: ...en reactivated The default for Announce Alarms is No Enable Freeze Alarm If there are one or more Thermostats or PESMs in a system they can also be used to detect a freeze condition See Freeze Alarm T...

Page 59: ...OCK 3 ON TIME CLOCK 3 OFF Time Clocks 2 and 3 is entered into the system and set for time and dates exactly like the settings for Time Clock 1 Latitude Longitude and Time Zone The system automatically...

Page 60: ...me when daylight savings time begins and ends LATITUDE 30 0 60 LATITUDE N S 1 1 NORTH 2 SOUTH LONGITUDE 90 0 180 LONGITUDE E W 2 1 EAST 2 WEST TIME ZONE 6 0 12 Daylight Savings Aegis 1000 automaticall...

Page 61: ...57 To change the DST Start or End Weekend press the key then use the arrow keys to scroll through the list Press the key to make the new selection...

Page 62: ...hrough the list of names To enter a name enter the two digit code shown in Table 2 in the Appendix for each character in the name then press the key Use the up arrow key to delete the most recently en...

Page 63: ...one has been entered by your installer To record your address Press 9 then enter the Master Code The Aegis 1000 will say RECORD ADDRESS then BEEP In a normal tone of voice say your name and address an...

Page 64: ...d to provide warning in the event of a fire It is your responsibility to plan your escape routes in the event of a fire alarm Your family should practice fire drills periodically to ensure that everyo...

Page 65: ...tice of changes so as to give you an opportunity to maintain uninterrupted service 6 In the event of equipment malfunction all repairs should be made by our company or an authorized agent It is the re...

Page 66: ...onnections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users sho...

Page 67: ...evice Fuse Polyfuse 9 A Output Fuse Polyfuse 3 A Battery Fuse Polyfuse 2 5 A Polyfuses are permanent fuses that do not need replacement Nominal Output Voltage 10 13 8 VDC Low Voltage Cut Out approx 9...

Page 68: ...CE 0 1 2 3 4 5 6 7 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 8 9 A B C D E F G H I J K L M N O 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 P Q...

Page 69: ...FIVE FIFTY SIX SIXTY SEVEN SEVENTY EIGHT EIGHTY NINE NINETY A M P M WELCOME TO AEGIS PAUSE SHORT PAUSE AC POWER ACCESS ADDRESS ALARM ALL 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56...

Page 70: ...OD BYE GOTO GUEST GUN HAD HALL HEAT HIGH HOLD HOURS HUNDRED INSTANT INTERIOR INVALID IS KITCHEN LEFT LEVEL 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 1...

Page 71: ...REMOTE REPEAT RESTORE RIGHT RISE ROOM SAVER SECONDS SECURE SECURITY SETTING SHOP SIDE SILENT SOUTH SPA STAIRS STAR STATUS STEPS STORAGE SUN SYSTEM OK TALK TAMPER TEMPERATURE TEN THEN 178 179 180 181 1...

Page 72: ......

Page 73: ...NOTE TO INSTALLER Following installation this manual shall be left for the homeowner s use 800 401 HOME 4663 www Aegishome com...

Reviews: