Page 19
Time Out
If you are called away from the keypad for any reason (to take a phone call, for instance) while you are engaged in an operation,
the keypad will "time out" and cancel it for you after 3 minutes. The display will return to the normal top-level display.
About Alarms
The Lumina system can monitor certain environmental conditions, such temperature and water, and can cause an alarm to alert
you of the potentially destructive condition (i.e. freezing temperatures, leaks or rising water indoors, etc.). If the Lumina system
detects one of these conditions, an alarm is activated as follows:
•
The keypad beeper will come on and emit a long steady tone.
•
The keypad display shows the type of alarm and the zones that have been tripped. For example:
WATER ALARM!
WATER SENSOR TRIPPED
•
The “When Alarm” macro is activated. This is a program that you create to alert you of the condition. You may have it
call you on your cell phone to alert you of the condition.
Silencing an Alarm
At any time, the alarm can be silenced by pressing the ' * ' key at the Lumina keypad. When the alarm is silenced, it may continue
to display the alarm condition (i.e. Water Sensor Tripped) until the condition is no longer present.
Trouble Indications
The Lumina constantly monitors the system and will alert you if it detects a trouble. The particular trouble is indicated on the
bottom line of the display and a trouble signal is given by beeping the keypad beeper continuously, 2 beeps per second.
When any trouble condition occurs, the keypad will beep twice per second and continue to beep until the ' * ' key (cancel) is
pressed to acknowledge the trouble. The keypad will say "TRBL NOW" (trouble now) if the trouble condition actually exists
while you are looking at the keypad. It will say "HAD TRBL" (had trouble) if the trouble occurred and then corrected itself.
The following are trouble indications and their meanings:
¾
ZONE NAME TRBL NOW or HAD TRBL:
If the reading for a zone becomes abnormal, trouble will be indicated on that
zone -
See
Status \ Test
. Excessive resistance in the contact and wiring usually causes trouble on zones. If the cause is not
obvious, call your installer for service.
¾
AC POWER OFF TRBL NOW or HAD TRBL:
Indicated if the normal house current powering the Lumina controller is
interrupted for more than 3 minutes. If this happens without good cause, check the wall mounted transformer to ensure that it
hasn't come out of the wall socket and check to see that the socket has power.
¾
BATTERY LOW TRBL NOW or HAD TRBL:
Every hour, the Lumina takes a dynamic test of the battery. If the battery
voltage is too low, then the keypad will indicate "BATTERY LOW". If this happens, make sure that the battery is connected.
The "BATTERY LOW" indication will remain until the next battery test is executed, 1 hour later, or when a Status | Test
command is executed.
¾
COMMUNICATOR TRBL NOW or HAD TRBL:
Indicated if the digital signal processor in the Lumina controller is no
longer working properly. Call your installer for service.
¾
FUSE TRBL NOW or HAD TRBL:
Indicated when the solid state fuse that protects the "Auxiliary" power supply opens.
The fuse will automatically reset when the fault condition is cleared.
¾
PHONE LINE DEAD TRBL NOW or HAD TRBL:
Indicated if the phone line is dead for more than 1 minute.