Page 20
To silence the trouble beeps on the keypad, press the ' * ' key. If more than one type of trouble has occurred, the display will
show each one for two seconds. Pressing the ' * ' key will acknowledge all trouble indications.
If the trouble condition occurs again, the keypad beeper will beep again -
See
Set Up Area, Beep On Trouble
if you wish to
disable the beeper.
¾
NO CONTROLLER DATA:
Indicated when keypad are no longer communicating with the controller. This may indicate a
wiring problem to the keypad or a more serious problem. Call your installer for service.
Codes
There are 16 user codes that you may assign to users of the system. All Lumina codes are 4 digits in length. A code can be any
number from 0001 to 9999. Each user should be assigned a code with an authority level, and times and days in which the code
will be valid -
See
Set Up Codes.
Codes are necessary to configure and program the system, access the system when it is set to High Security Mode, change
Lumina mode when it is set to High Security Mode, to access the system via remote telephone access, and to access the system
using HAI PC Access Software and HAI Web-Link II Software.
The levels of authority that you can assign to a user code are Master, Manager, and User.
Master Code
The Master code allows complete access to the entire system. Only the owner(s) or the one(s) who will govern the system should
have and use the master code. User Code 1 is always set to a Master code -
See
Set Up Codes.
Manager Code
Manager codes, during valid times/days, can access the Main Menu and change Lumina mode when the system is in High
Security Mode. Managers may also access the system via local or remote telephone access and access HAI Web-Link II.
User Code
User codes, during valid times/days, can only be used to change Lumina mode when High Security Mode is enabled, and access
HAI Web-Link II.
Lumina Maintenance
Your Lumina controller and the keypads are designed to require very little maintenance.
Keypads can be cleaned using a mild detergent and a soft cloth.
Every three years, or if the "BATTERY LOW TROUBLE NOW" indication comes on and stays on for an extended period
without reason, the rechargeable battery in the controller should be replaced. The recommended battery type is a 12-volt, 5 amp-
hour sealed lead-acid battery.
To replace the battery, disconnect the red battery wire from the battery (+) terminal. Cover the connector at the end of the wire
with electrical tape to avoid its touching anything in the enclosure. Disconnect the black wire from the battery (-) terminal and
cover the connector at the end of the black wire with tape. Remove the old battery. Install the new battery by reversing the
removal procedure.
Be very careful to connect the Black wire to the (-) terminal on the battery and the Red wire to the (+) terminal.
Summary of Contents for lumina
Page 2: ...Copyright 2001 2006 Home Automation Inc All Rights Reserved...
Page 114: ......
Page 115: ......
Page 116: ...HAI New Orleans LA U S A...