Page 82
Installer Setup
This section describes the items that the installer must setup as part of system installation. When selected, the installer is
presented with a new menu group. To enter the
Installer Setup
menu, from the Setup menu, press the 9 (INST) key.
INSTALLER
SETUP
MENU:
1=CTRL 2=ZONE 5=TEMP
↓
6=MISC
7=EXP
↑
Setup Control
To configure various X-10 and UPB settings, from the Installer Setup menu, select the 1 (CTRL) key.
X-10 House Code
The base X-10 house code must be specified. The base house code is the house code for X-10 units 1-16 and is referenced as
house code 1. The house code for the X-10 units 17-32 is the next house code after the base house code, or house code "B" if the
base house code is "A". House codes C and D follows for Units 33-64 (in groups of 16), respectively.
X-10 HOUSE CODE: A
1-16=A-P
↓
UPB Network ID
The Network ID is a unique number between 1 and 255 which identifies your UPB Network.
UPB NETWORK ID: 1
1-255
Enter the UPB Network ID (1-255) followed by the ' # ' key.
UPB Password:
The Network Password is a 4-digit number between 0001-FFFF that is used to protect your UPB network from unauthorized
changes to the internal settings of your UPB devices.
UPB PASSWORD: 1234
0000-FFFF
Enter the UPB Password (0000-FFFF) followed by the ' # ' key.
To enter the digits A-F, first press the “HOME” key, then press the 0-5 key respectively (i.e. “1A2B” = 1 HOME 0 2 HOME 1 #).
UPB Status Time (Status Tracking):
When using HLC, “Status Tracking” is used to update the status of each HLC device in a room whenever a scene is executed in
that room. For example, the scene “A” button is pushed on a Room Controller in the Living Room. All of the lighting loads in
the Living Room are changed, but the status for the individual lighting loads isn’t updated in Lumina until a status request
message is sent to each unit. When “Status Tracking” is enabled, this is done automatically after a scene is executed.
The value set for the UPB Status Time is the amount of seconds that the Lumina controller waits before requesting status after a
scene is executed. By default, the time is set to 5 seconds. This gives lighting loads (with varying fade rates) the necessary time
to “settle down” before the status is requested.
UPB STATUS TIME: 5
0-255 SECONDS
Enter 1-255 for 1 to 255 seconds. Enter 0 to disable “Status Tracking”.
Note:
“Status Tracking” must be enabled for Lumina to accurately set the LED indicators on Room and House Controllers.
Summary of Contents for lumina
Page 2: ...Copyright 2001 2006 Home Automation Inc All Rights Reserved...
Page 114: ......
Page 115: ......
Page 116: ...HAI New Orleans LA U S A...