Page 1
EARTH
GROUND
SWITCHED
12 VDC
AUXILIARY 12 VDC
KEYPAD(S)
NOTES:
1. SWITCHED 12V, AUXILIARY 12V, CONSOLE, AND OUTPUTS 1-8 ARE INCLUDED IN THE TOTAL DEVICE LOAD, WHICH CANNOT EXCEED 1 AMP.
2. OUTPUTS LABELED "INT" AND "EXT" CANNOT EXCEED 1 AMP, SPLIT BETWEEN THE TWO OUTPUTS.
HAI REMOTE
CONTROL
THERMOSTAT(S)
1A Max.
(See NOTE 1)
1A Max.
(See NOTE 1)
(See NOTE 2)
WARNING
TO PREVENT RISK
FROM ELECTRIC SHOCK,
DE-ENERGIZE THIS
UNIT AND DISCONNECT
TELEPHONE LINES
BEFORE SERVICING.
100 mA Max. (See NOTE 1)
OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT
ALL CIRCUITS EXCEPT FOR THE BATTERY
ARE POWER-LIMITED (CLASS II)
CONNECT CABLE
TO CONTROLLER,
PLUG MODULAR
END INTO
RJ31X JACK
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONES 1-16 ARE CONFIGURABLE FOR AUXILIARY OR TEMPERATURE.
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
ZONE
INPUT
ZONE
INPUT
ZONE
ZONE
INPUT
INPUT
ONLY ZONES 9-16 MAY BE CONFIGURED AS ENERGY SAVER ZONES.
ONLY ZONE 16 MAY BE USED FOR HAI REMOTE CONTROL THERMOSTATS.
OUTPUT
OUTPUT
1 Amp Max.
11A02-2
6' KEYPAD
CABLE (Supplied)
OUTPUT
BLACK WIRE TO -
RED WIRE TO +
BATTERY
12V 5AH
OR EQUIVALENT
POWER CELL PC5-12
6 CONDUCTOR CABLE (SUPPLIED)
RE
D
BL
A
C
K
YE
LL
O
W
G
R
EEN
FI RE
EVENTS
CANCEL
MESSAGE
ME NU
A UX
SETUP
BUTTONS
STATUS
CONTROL
S ECURITY
ALL
TEMP
POL
<Program
Status
Powerline Interface Module
UPB™
OR EQUIVALENT
MODEL RT-R2440SL/M
REVERE
POWER TRANSFORMER
24 VAC 40 VA
44A07-1
TRANSFORMER
CABLE (Supplied)
44A07-1
TRANSFORMER
CABLE (Supplied)
YE
L
LO
W
BLACK / RED
GREEN
PLANNING
Before you start, the Lumina system should be planned as follows:
Thoroughly review Appendix A “Understanding HLC” for an overview of an HLC system.
Complete the worksheet(s) in Appendix B “HLC Planner” to plan the lighting scheme for each room.
Give consideration to where the controller will go. Remember that it needs a duplex receptacle not controlled by a switch,
preferably on its own circuit, within 5 feet of the controller.