background image

Page 6 

SETUP 

 
The Setup menu is used to configure the system and to give text descriptions to all of the HLC lighting devices.  To enter the Setup 
menu, from the top-level display or from the main menu, press the 9 (SETUP) key on the numeric keypad. 
 
Upon entry to the Setup mode, you will first be prompted to enter a valid code: 
 

 

 

SET UP

 

   ENTER 

CODE:

 

 
Use the default code to enter the Setup mode (the default code is 1 1 1 1): 
 

 

 

 

SET UP

 

 

 

 

1=CODES 2=TIME  3=PROG 

 

 

 

 

 

4=DIAL  5=AREA   6=MISC 

 

 

 

 

7=NAMES 8=VOICE        

 

 

Set the Time and Date 

 
To set up time and date, from the Setup menu, press the 2 (TIME) key.  You will be prompted to enter the new time and date.  
AM/PM must be specified for the time if that format is being used, otherwise the entered time should be 13:00-23:59.  
 

 

 

 

TIME: 

 

   HHMM 



=AM 

=PM 

 

 
   DAYLIGHT 

SAVINGS 

TIME?

 

   0=NO 

 

1=YES

 

 
If Daylight Savings Time is currently being observed (between spring and fall), set this item to "Yes".  If Daylight Savings Time is not 
currently being observed (between fall and spring) or is not observed in your geographic location, set this item to "No".  This item is 
used to correctly calculate the times for sunrise and sunset.  Once the time is set, the Lumina controller will automatically adjust the 
"time of day" each time daylight savings time begins and ends. 
 
Next you are prompted to enter the date.  If the current date is February 8, 2006, enter it as “0 2 0 8 0 6”. 
 

   ENTER 

DATE:

 

   MMDDYY

 

 

 
Assign a Name to HLC Lighting Devices 

 
Before naming HLC Dimmers, Switches, and 6-Button Room Controllers, you should have thoroughly reviewed Appendix A 
“Understanding HLC” and have completed the worksheet(s) in Appendix B “HLC Planner”. 
 
You should assign a name to the following HLC devices: 
 

 

Name the Room Controllers that resides on the 1

st

 unit in each Room (i.e. Unit 1, 9, 17, 25, etc.) 

 

Name all of the Lighting Loads (Dimmers and Switches) in each Room 

 
You should not assign a name to the following HLC devices: 
 

 

Do not name Room Controllers that reside between the 2

nd

 and 7

th

 unit in a Room

 

Do not name House Controllers that reside on the 8

th

 unit in a Room

 
 

Summary of Contents for lumina

Page 1: ...HOME AUTOMATION INC Lumina and Lumina Pro Lighting and Automation System Quick Start Installation Guide Document Number 44I00 1 Rev 2 12 February 2006...

Page 2: ...g instructions please download the following document s from the HAI web site 44R00 1 Lumina Advanced Application Guide 44R00 2 Lumina Pro Advanced Application Guide www homeauto com Copyright 2006 Ho...

Page 3: ...NE ZONE INPUT INPUT ONLY ZONES 9 16 MAY BE CONFIGURED AS ENERGY SAVER ZONES ONLY ZONE 16 MAY BE USED FOR HAI REMOTE CONTROL THERMOSTATS OUTPUT OUTPUT 1 Amp Max 11A02 2 6 KEYPAD CABLE Supplied OUTPUT B...

Page 4: ...ROUND THE LUMINA CONTROLLER S EARTH GND TERMINAL TO A COLD WATER PIPE OR TO A 4 FOOT GROUND ROD TO PRESERVE ITS BUILT IN TRANSIENT PROTECTION USE 14 GAUGE WIRE TRANSIENT PROTECTION WILL NOT WORK IF TH...

Page 5: ...ith a screwdriver c Mount the back plate to the wall Mounting holes are designed to fit on a single or double gang box or directly to the wall d Plug the cable into the connector on the keypad Printed...

Page 6: ...ed POWER TRANSFORMER 8 Connect the Battery Unplug the Power Transformer to shut down the controller Connect the black battery wire to the negative battery terminal of the supplied battery Connect the...

Page 7: ...nu before selecting a function if the number for the desired menu item is known Error Beeps If you press a key that is invalid for the function that you are doing the keypad will beep 3 times indicati...

Page 8: ...ime is not currently being observed between fall and spring or is not observed in your geographic location set this item to No This item is used to correctly calculate the times for sunrise and sunset...

Page 9: ...Load names Use the up arrow and down arrow keys to scroll through the list of available names for the device When appropriate name appears press the key to select that name for the device The name no...

Page 10: ...nfigure each device as follows STEP 1 On the Lumina keypad from the top level display press 6 STATUS and then press 1 CTRL The first named unit is displayed Living Room STATUS OFF STEP 2 Configuring R...

Page 11: ...it in Setup mode as follows Lighting Load Setup Step Operation 1 Tap the rocker switch quickly 5 times 2 The HAI UPB Wall Dimmer or Switch will flash the lighting load one time and blink its LED blue...

Page 12: ...s CONFIGURE UNIT 2 COMPLETED Once completed press the key to return to the Status display Repeat Step 5 for each unnamed Room Controller STEP 6 Configure Unnamed House Controllers House Controllers th...

Page 13: ...D and one On Scene preset lighting levels for each device when the room is turned on To set a lighting scene using a Room Controller Each lighting scene can also be set or easily changed using the pus...

Page 14: ...sired lighting levels may be set manually at the switch by pressing the top of the paddle to brighten the light or the bottom of the paddle to dim the light 2 After the desired lighting levels are set...

Page 15: ...E CONTROLLER UNIT 48 HLC LOAD OR HOUSE CONTROLLER UNIT 56 HLC LOAD OR HOUSE CONTROLLER UNIT 64 UNIT 1 ROOM 2 UNIT 9 ROOM 3 UNIT 17 ROOM 4 UNIT 25 ROOM 5 UNIT 33 ROOM 6 UNIT 41 ROOM 7 UNIT 49 ROOM 8 UN...

Page 16: ...are used the first Room Controller should be set to the first unit number in the group i e Unit 1 Room 1 additional Room Controllers can be used by setting each to any other unused unit number in the...

Page 17: ...m is turned on the LED indicator behind the respective button is illuminated and all of the lights in the room are turned on When the room is turned off the LED indicator behind the respective button...

Page 18: ...er which controls up to 8 Rooms ROOM 1 Living Room Unit Unit Number HLC Device Type Name 1st Unit 1 Room Controller Living Room 2nd Unit 2 Lighting Load Room Controller 3rd Unit 3 Lighting Load Room C...

Page 19: ...16 Lighting Load House Controller ROOM 3 Unit Unit Number HLC Device Type Name 1st Unit 17 Room Controller 2nd Unit 18 Lighting Load Room Controller 3rd Unit 19 Lighting Load Room Controller 4th Unit...

Page 20: ...m Controller 4th Unit 52 Lighting Load Room Controller 5th Unit 53 Lighting Load Room Controller 6th Unit 54 Lighting Load Room Controller 7th Unit 55 Lighting Load Room Controller 8th Unit 56 Lightin...

Page 21: ...se Controller ROOM 12 Unit Unit Number HLC Device Type Name 1st Unit 89 Room Controller 2nd Unit 90 Lighting Load Room Controller 3rd Unit 91 Lighting Load Room Controller 4th Unit 92 Lighting Load Ro...

Page 22: ...ghting Load Room Controller 5th Unit 125 Lighting Load Room Controller 6th Unit 126 Lighting Load Room Controller 7th Unit 127 Lighting Load Room Controller 8th Unit 128 Lighting Load House Controller...

Page 23: ...nit Unit Number HLC Device Type Name 1st Unit 161 Room Controller 2nd Unit 162 Lighting Load Room Controller 3rd Unit 163 Lighting Load Room Controller 4th Unit 164 Lighting Load Room Controller 5th U...

Page 24: ...Lighting Load Room Controller 6th Unit 198 Lighting Load Room Controller 7th Unit 199 Lighting Load Room Controller 8th Unit 200 Lighting Load House Controller ROOM 26 Unit Unit Number HLC Device Type...

Page 25: ...troller 7th Unit 231 Lighting Load Room Controller 8th Unit 232 Lighting Load House Controller ROOM 30 Unit Unit Number HLC Device Type Name 1st Unit 233 Room Controller 2nd Unit 234 Lighting Load Roo...

Reviews: