Page 11
Police Emergency
When the 1 key and the 3 keys are pressed simultaneously, the Police Emergency alarm is activated. This alarm operates exactly
the same as described for Burglar Alarm Activated except:
•
The console display indicates: "BURGLARY! - POLICE EMERG TRIPPED".
•
The interior sounder and the outdoor siren are activated immediately. There is no outside siren delay.
Fire Emergency
When the 4 key and the 6 key is pressed simultaneously, the Fire Emergency alarm is activated. This alarm operates exactly the
same as described for Police Emergency Button except:
•
The sounders activates in a 3 pulse temporal pattern distinguish the fire alarm from the burglar alarm.
•
The console display will read: "FIRE ALM - FIRE EMERG TRIPPED".
The Fire Emergency alarm can be turned off at any time by pressing the ' * ' key.
Auxiliary Emergency
When the 7 key and the 9 key is pressed simultaneously, the Auxiliary Emergency alarm is activated.
•
The console beeper comes on - display indicates: "AUX ALARM! AUX EMG BTN TRIPPED".
•
The console beeper continues to sound until the alarm is reset.
Duress Code Entered or Duress Alarm Activated
(
See
Duress Code
for a description of when to use)
In the event that you enter your duress code or a Duress zone is tripped, the system performs a silent dial out as follows:
•
No alarms, lights or console beepers are activated. The system does not display the duress alarm.
•
The system waits the dial out delay, then begins to dial out.
If you are having your system monitored, the central station will be sent a code representing a silent alarm (duress).
Alarm Reset
The alarm system will reset itself after the outside siren has been on for 1-30 minutes. When the alarm system resets, any zone
that is
ready
is reactivated, so the alarm system will be activated again if the zone is tripped. If a zone remains
not ready
(i.e. a
door has been left open) it will be automatically bypassed when the alarm resets.
Alarm Cancel
At any time, you can silence your alarm system by pressing the Off key and entering your code. If the system has reported, or is
in the process of reporting an alarm to a central station, it will send the alarm code followed by a code indicating that the user has
canceled the alarm. If an alarm is canceled before the dial out delay has expired, the system will not report any alarm.
If an alarm is canceled during a voice dial out, the system hangs up immediately.
Summary of Contents for OMNI II
Page 2: ...Copyright 2001 2002 Home Automation Inc All Rights Reserved...
Page 77: ......