Page 58
Enable Freeze Alarm
If there are one or more Thermostat or PESM in a system, they can also be used to detect a freeze condition -
See
Freeze Alarm
.
The default for
Enabled Freeze Alarm
is No.
Flash For Alarm
You may enter one unit number that will flash on and off continuously when the alarm is activated. This should be an outside
light to alert neighbors and police to your property if the alarm is activated.
The default
Flash For Alarm
is Unit 2. You may enter one number for the unit number you wish to have flash, or ' 0 ' for none.
X-10 House Code 1 Format
House Code 1 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), and Lightolier's
Compose Mode transmission format.
X-10 HC 1 FORMAT: 1
1=EXTENDED #=CHNG
↕
To change format for House Code 1, press the ' # ' key, then use the arrow keys to scroll through the list of formats. Press the ' # '
key to select a new type
.
FORMAT
NUMBER
DESCRIPTION
STANDARD
0
Preset Dim Command (X-10, X-10 Pro, PCS, etc.)
EXTENDED
1
Extended Code Level Command (Leviton)
COMPOSE
2
Compose Mode (Lightolier's Compose)
The default setting for X-10 HC 1 Format is 1.
X-10 House Codes 2-4 Format
House Codes 2-4 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), and
Lightolier's Compose Mode transmission format.
X-10 HC 2 FORMAT: 1
1=EXTENDED #=CHNG
↕
The default setting for X-10 HC 2-4 Format is 1.
House Code 1 X-10 All Off
This feature allows you to choose if X-10 House Code 1 or ALC Branch 1 will respond to All Off commands.
HC 1 X-10 ALL OFF: 1
0=NO 1=YES
↕
To turn
HC 1 All Off
feature On, press 1 then ' # '. To turn
HC 1 All Off
feature Off, press the 0 key, then ' # '.
The default setting for
HC 1 X-10 All Off
is Yes.
House Code 1 X-10 All On
This feature allows you to choose if X-10 House Code 1 or ALC Branch 1 will respond to All On commands.
HC 1 X-10 ALL ON: 1
0=NO 1=YES
↕