Page 31
INSTALLER SETUP
This section describes the items that the installer must setup as part of system installation. The Installer Setup mode is used to
configure the general operation of the system, the Outputs, the Areas, the Zone Types, the Digital Communicator, and various
other settings. This information is covered only in this manual. All other SETUP items, including delay times, names and voices,
voice dialer, and codes are covered in the Owner's Manual, Document No. 20R00-1.
SETUP items are stored permanently in the system, even if the battery and AC power are disconnected. The "default" settings are
the ones that have been set at the factory. You can review or change the setup items easily, as shown below.
Note:
The default Installer Code is 1111.
To access the SETUP menu, press the 9 key and enter the installer code. To access the INSTALLER SETUP menu, press the #
(INST) key.
INSTALLER
SETUP
MENU:
1=CTRL 2=ZONE 3=DCM
↓
4=AREA 5=TEMP 6=MISC
7=EXP
↑
SETUP CONTROL
To configure X-10 and voltage outputs, from the Installer Setup menu, select the 1 (CTRL) key.
The base X-10 house code must be specified, as well as the output type for each of the 8 voltage outputs. The output type for
both the interior and exterior horns may also be changed.
Press (
"
) to advance to the next item, (
!
) to go back.
X-10 HOUSE CODE
The base house code is the house code for units 1-16 and is referenced as house code 1. The house code for the units 17-32 is the
next house code after the base house code, or house code "B" if the base house code is "A". House codes "C" and "D" follows for
Units 33-64.
X-10 HOUSE CODE: A
1-16=A-P
↓
X-10 3-PHASE
This setting is used to select whether the X-10 signal is transmitted only at zero crossing for single phase (120V/240V) electrical
systems or is transmitted at 0, 60, and 120 degrees for three phase electrical systems.
X-10 3-PHASE: 0
0=NO 1=YES
↕
To turn 3-Phase On, press 1 then ' # '. To turn 3-Phase Off, press 0 then ' # '. The burst at 60 and 120 degrees will be eliminated.
The default setting for 3-Phase is No.