Page 36
TAMPER ZONES should be used for items such as gun cabinets and liquor closets.
LATCHING TAMPER ZONES ignore the status of that zone during power cycles.
POLICE EMERGENCY
This zone type activates the burglar alarm and sounder. An emergency dial out is activated after the DIAL OUT DELAY.
DURESS EMERGENCY (SILENT DIAL OUT)
If you wish to have a button in your home that activates a SILENT dial out, (no lights flashing and no sounder) it should be
connected to a zone that is configured as a DURESS EMERGENCY. If this zone is accidentally tripped, you will not know that
the Omni II is making a silent dial out, and hence won't know to stop it.
To stop a silent dial out once it has started, you must go to the console and press OFF then enter your code.
SUPERVISED FIRE
Any zone can be programmed as a SUPERVISED FIRE ZONE. In UL Listed Installations, all fire detectors must be configured
as a SUPERVISED FIRE ZONE and connected as shown in this manual. When Zones 1-4 are configured as a SUPERVISED
FIRE ZONE, the corresponding Zone Jumpers (JP11-JP14) must be in the "SMK" (smoke) position.
FIRE EMERGENCY
This zone type activates the fire alarm for a normally closed (open for alarm) and open collector (short to ground for alarm)
switches. It is not supervised as required for UL Listed Installations and shall NOT be used in such installations.
GAS
This GAS ZONE will generate an alarm, activate the sounder (on - off - on - long off), and make a dial out. This zone type
requires an external 1000-ohm end-of-line resistor.
When Zones 1-4 are configured as a GAS ZONE, the corresponding Zone
Jumpers (JP11-JP14) must be in the "SMK" (smoke) position.
AUXILIARY EMERGENCY
This AUXILIARY EMERGENCY ZONE type will generate an alarm (console beeper - no sirens) and make an emergency dial
out when the zone is violated. An emergency dial out is activated after the DIAL OUT DELAY.
TROUBLE
This zone type can be used to monitor the status of an external device, such as the battery status of a wireless security receiver. It
can also used to record events in the event log (i.e. driveway activation, opening of a gate, etc.) without setting off the alarm.
When the zone is tripped, the zone name will be displayed on the display as "NOT RDY". The alarm is not activated, regardless
of the security mode. The trouble is logged in the event log. The digital communicator (if used) will report the alarm code for the
zone. The voice dialer will not be activated.
FREEZE
This FREEZE ALARM ZONE type will generate an alarm (console beeper, no sirens) and make an emergency dial out.
WATER
This WATER ALARM ZONE type will generate an alarm (console beeper, no sirens) and make an emergency dial out.
Summary of Contents for OMNI II
Page 2: ......
Page 21: ...Page 15 BLACK RED RED FIGURE 7 SOUNDER CONNECTIONS...
Page 67: ......
Page 68: ...HAI New Orleans LA U S A...