Page 26
Controlling ALC or X-10 Units
Entry
Lights
0=OFF
1=ON
2=DIM
3=BRT
↓
Entry
Lights
4=LVL
5=RMP
9=TIM
#=STA
↑
Press 0 (OFF) to turn the selected unit off.
¾
Press 1 (ON) to turn the selected unit on.
¾
Press 2 (DIM) to dim the selected unit (1-9 steps, each step is 10% from its current level).
¾
Press 3 (BRT) to brighten the selected unit (1-9 steps, each step is 10% from its current level).
¾
Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%).
¾
Press 5 (RMP) to ramp the lighting level of an ALC Dimmer Switch to a new level at a selectable ramp rate.
•
5 (RMP) does not affect X-10 units.
¾
Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18
hours.
¾
Press # (STA) to view the current status of the unit.
Ramp Command (ALC)
When ALC Switch Modules are being used, it is possible to ramp the lighting level of an ALC Dimmer Switch to a new level at a
selectable ramp rate. Only ALC Dimmer Switches respond to the Ramp command.
Press the 5 (RAMP) key to select the ramp command. The keypad will then prompt you for the desired ramp rate:
ENTER
RATE:
MINUTES (1-99) #=H/M/S
The rate specifies the time it takes the switch to go from full off to full on, or from full on to full off. Thus a level change from
full off to 50% on will take half the time specified.
Before any digits are entered, the ' # ' key may be used to switch between specifying the rate in minutes, seconds, and hours.
After you choose between minutes, seconds, and hours, enter the rate (2-99 seconds, 1-99 minutes, or 1-10 hours).
Next, enter a number (0-100) to indicate the final lighting level (intensity) desired.
LIGHTING LEVEL:
0-100%:
The keypad will beep and the lighting level will be adjusted. The keypad display top line will read:
Entry Lights 40% AT 1H
Summary of Contents for OMNI IIe
Page 2: ...Copyright 2001 2009 Home Automation Inc All Rights Reserved ...
Page 116: ......
Page 117: ......