Page 30
Leviton Scene Control
Omni IIe supports Leviton Scene Control (a feature found in certain Leviton Switches). There are 64 Scenes that can be set and
executed. The Leviton Switches are divided into "lighting groups" of four units each. Each of these lighting groups can be set to
four different Scenes. Once the Scenes have been set up, a command can be sent to the units in that Scene to simultaneously
return to the preprogrammed lighting level.
Scene
There are 64 Leviton Scenes that can be set and executed. The X-10 units (unit numbers 1-64) are divided into "lighting groups"
of four units each. Each of these lighting groups can be set to four different Scenes. Scenes 1-4 apply to the first four unit
numbers (units 1-4), Scenes 5-8 to the next four unit numbers (units 5-8), and so on. Thus an easy correspondence is made
between Scene numbers and unit numbers.
SCENES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
X
X
X
X
2
X
X
X
X
3
X
X
X
X
4
X
X
X
X
5
X
X
X
X
6
X
X
X
X
7
X
X
X
X
8
X
X
X
X
9
X
X
X
X
10
X
X
X
X
11
X
X
X
X
12
X
X
X
X
13
X
X
X
X
14
X
X
X
X
15
X
X
X
X
UNIT
N
U
M
BERS
16
X
X
X
X
X - Corresponds to the unit numbers in a Scene.
Scene Commands
Scene Commands are used to Set Scenes, issue a Scene On command, and issue a Scene Off command. To issue Scene
Commands, press the 2 (SCENE) key. You are prompted to enter a Scene number.
ENTER SCENE:
1-64
Enter the Scene number (1-64) followed be the ' # ' key.
SCENE 1
0=OFF 1=ON 2=SET
Scene Set Command
The Scene Set command is used to set up Scenes for a lighting group. Set the desired lighting level for each of the units in the
lighting group for the first Scene. The desired lighting level may be set manually at the switch, or by a command issued from the
controller. After the desired lighting levels are set, press the 2 (SET) key to save the first Scene for that group. Commands are
sent to each of the four units in that group to instruct each unit to save its current lighting level as the lighting level for the Scene.
Repeat these steps to set up each of the remaining three Scenes for that lighting group.
Scene On Command
Once the Scenes have been set up, press the 1 (ON) key to command the four units in that Scene to return to the lighting level set
by the Scene Set command for that Scene.