Page 57
If Daylight Savings Time is currently being observed (between spring and fall), set this item to "Yes". If Daylight Savings Time
is not currently being observed (between fall and spring) or is not observed in your geographic location, set this item to "No".
This item is used to correctly calculate the times for sunrise and sunset.
You are only asked this question when you set the time. Once the time is set, Omni IIe will automatically adjust the "time of day"
each time daylight savings time begins and ends.
Finally, you are prompted to enter the current date:
ENTER
DATE:
MMDDYY
Enter the current date. If the current date is February 8, 2006, enter it as “0 2 0 8 0 6”.
Advanced Control Programming (ACP)
Your Omni IIe can be programmed to do automated control and security functions on a time schedule or in response to an event
occurring in the system. You may program the following items:
•
Unit Numbers: On, Off, On for time, Off for time, Dim, Brighten, Dim for time, Brighten for time, Level, and Scene
•
Settings for HAI Communicating Thermostats
•
PESM control: On, Off, On for time, Off for time, and Heat and Cool setback temperatures
•
Temperatures: Low and High temperatures
•
All lights On, All Off
•
Security modes Off, Day, Night, Away, Vacation, Day(Instant), and Night(Delay) and bypass and restore zones
•
Buttons (Events)
•
Messages: Show, Log, Clear, Say, Phone, and Send
The Omni IIe executes programs:
•
Once at a certain time on a certain date (One-Time Program)
•
On a certain date every year (Yearly Program)
•
Repeatedly (Repeating Programs)
•
In response to an event (Button Programs)
You can also specify 2 conditions in each program, so that they only run under certain circumstances.
Every line of programming in the Omni IIe controller consists of three pieces. Each line
must
have at least an event (when) and a
result (command). The "&IF" statement (condition) is optional in all programming lines.
The program may specify up to 2 conditions that must be true for the program to execute. When programming from the console,
only 1 condition can be selected. If 2 conditions must be specified for a single program line, it must be entered using the PC
Access Software.
Each program can be set up to execute at a certain time of day or on the occurrence of a particular event in the system. When this
time or event occurs, the programmed action will be taken if, and only if, the specified condition(s) is also true at that time.
The Program menu allows you to add, review, change, and delete automation programs. To enter the Program menu, from the
Setup menu, press the 3 (PROG) key.
SET
UP
PROGRAMS
1=ADD 2=SHOW 3=DELETE
Summary of Contents for OMNI IIe
Page 2: ...Copyright 2001 2009 Home Automation Inc All Rights Reserved ...
Page 116: ......
Page 117: ......