Console 1-8 Audible Exit Delay
Consoles (and touchscreens) 1-8 can be configured to beep while the exit delay is in effect. During the last 10 seconds of the exit
delay, the audible indication will beep twice as fast to let you know that you must leave at once.
Press the 0 key to select “No” (this console will not beep during the exit delay) or the 1 key to select “Yes” (this console will beep
during the exit delay). After selecting, press the down-arrow key to change this option for the next console.
CONSOLE 1 AUD EXT: 1
0=NO 1=YES
The default setting for
Console 1-8 Audible Exit Delay
is Yes
House Codes 1-4 Format
House Codes 1-4 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightolier's
Compose Mode, UPB (open transmission format), Lutron’s RadioRA transmission format, HAI Lighting (HLC), and CentraLite
transmission format.
HC 1 FORMAT: 5
HAI LIGHTING #=CHNG
To change format for House Code 1, press the ' # ' key, and then use the arrow keys to scroll through the list of formats. Press the
' # ' key to select the desired format
.
After selecting, press the down-arrow key to change format for the next House Code.
FORMAT NUMBER
DESCRIPTION
STANDARD
0
Preset Dim Command (X-10, X-10 Pro, Leviton, PCS, etc.)
EXTENDED
1
Extended Code Level Command (Leviton)
COMPOSE
2 Compose
Mode
(Lightolier's
Compose)
UPB
3 Universal
Powerline
Bus
(open
format)
RADIO
RA
4 Lutron
RadioRA
HAI
LIGHTING
5 HAI
Lighting
Control
(HLC)
CENTRALITE
6 CentraLite
Lighting
VIZIA RF Z-WAVE
7
Vizia RF Z-Wave
The default setting for HC 1-4 Format is 5 (HLC).
House Codes 1-4 All Off
This feature allows you to choose if House Code 1-4 will respond to the “All Off” command. Press the 0 key to select “No” and
the 1 key to select “Yes”. After selecting, press the down-arrow key to change this option for the next House Code.
HC 1 ALL OFF: 1
0=NO 1=YES
The default setting for
HC 1-4 All Off
is Yes.
Notes:
1.
When configured, each House Code will affect 2 rooms of HLC or Vizia RF Z-Wave lighting (i.e. HC 1 ALL OFF affects
Room 1 and 2).
2.
When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All Off” does not affect the state of the
installed devices; however, if this setup item is set to “Yes”, Omni IIe will change the status of all units on that House Code
to “Off” (even though it doesn’t explicitly send an All Off command to those units). If the “House Code All Off” setup item
is set to “No”, Omni IIe will not change the status of units on that House Code.