Page 20
The first unit number in each room (i.e. 1, 9, 17, 25, etc.) is reserved for controlling the room. The name for this unit should
reflect the room name (e.g. Kitchen, Great Room, Theater, etc.). Vizia RF or Z-Wave lighting devices cannot be associated with
these unit numbers.
If one or more pushbutton controllers are used, the first pushbutton controller should be set to the first unit number in the group
(i.e. Unit 1); additional pushbutton controllers can be used by setting each to any other unused unit number in the group
(i.e. Units 2-8).
Using a console, touchscreen, or other interface to OmniPro II, the room can be turned off (all loads in the group are turned off),
turned on (all loads in the group are turned on), or set to one of 4 lighting scenes (A-D).
About CentraLite
CentraLite is a centralized lighting control system that uses hardwired lighting control or wireless radio frequency technology to
control lighting loads, fans, and mechanical low voltage relays.
CentraLite lighting scenes are used to control groups of lights which are preset to turn on to various levels of dimming.
When set to CentraLite, the OmniPro II controller can:
¾
Send commands (on, off, and level) to individual loads and relays
¾
Receive status (on and off) from individual loads and relays
¾
Execute scene commands (on and off) to control lighting scenes
¾
Receive commands when buttons are pressed on a CentraLite keypad
About Lutron RadioRA
Lutron RadioRA uses wireless communication technology to control lighting. Each Switch or Dimmer controls one Zone, or area,
of lighting in a RadioRA system. Accessory Switches and Dimmers are used to control the lights locally from up to 9 additional
locations. Master controls provide control and monitoring for all the lights in a RadioRA system.
Phantom Buttons are “virtual” buttons in the RS232 Interface. Though there are no physical buttons that represent these Phantom
Buttons, they work very similarly to buttons on RadioRA Master Controls. Phantom Buttons are intended to give the RS232
Interface control over multiple RadioRA Switches and Dimmers with one command. To control more than one device at one time,
Phantom Buttons are recommended.
A Zone is any individual RadioRA Switch or Dimmer. A RadioRA System has a maximum of 32 Lighting Zones. Zone Numbers
can be used to identify any individual Zone (one Switch or one Dimmer), in a RadioRA system via the RS232 Interface. The
Chronos System Bridge and Timeclock bridges two RadioRA systems for a total of 64 Lighting Zone Controls and 24 Master
Controls.
When set to RadioRA, the OmniPro II controller can:
¾
Send commands (on, off, and level) to individual Switches and Dimmers
¾
Receive status (on and off) from individual Switches and Dimmers
¾
Receive commands when buttons are pressed on Master Controls
¾
Execute Phantom Button commands
Summary of Contents for Omni Pro II