Page 26
Controlling RadioRA Units
Entry Lights
0=OFF 1=ON 2=DIM 3=BRT
↓
Entry Lights
4=LVL 5=RMP 9=TIM #=STA
↑
¾
Press 0 (OFF) to turn the selected unit off
¾
Press 1 (ON) to turn the selected unit on.
¾
2 (DIM) does not affect RadioRA units.
¾
3 (BRT) does not affect RadioRA units.
¾
Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%).
¾
5 (RMP) does not affect RadioRA units.
¾
Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18
hours.
¾
Press # (STA) to see the status (On or Off) of a RadioRA device.
Note:
When a RadioRA device transmits a signal (i.e. Switch or Dimmer is turned on or off locally, Mater Control button is
pressed, or Phantom Button is executed), OmniPro II will automatically update the status of each affected device.
Controlling ALC or X-10 Units
Entry
Lights
0=OFF
1=ON
2=DIM
3=BRT
↓
Entry
Lights
4=LVL
5=RMP
9=TIM
#=STA
↑
¾
Press 0 (OFF) to turn the selected unit off.
¾
Press 1 (ON) to turn the selected unit on.
¾
Press 2 (DIM) to dim the selected unit (1-9 steps, each step is 10% from its current level).
¾
Press 3 (BRT) to brighten the selected unit (1-9 steps, each step is 10% from its current level).
¾
Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%).
¾
Press 5 (RMP) to ramp the lighting level of an ALC Dimmer Switch to a new level at a selectable ramp rate.
•
5 (RMP) does not affect X-10 units.
¾
Press 9 (TIM) to time the selected unit (On or Off). Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18
hours.
¾
Press # (STA) to view the current status of the unit.