Page 29
Controlling Outputs
The OmniPro II has eight outputs that can be used to switch relays. Outputs 1-8 are controlled as Unit Numbers 385-392,
respectively. If the Interior Horn is configured as a "General Purpose" output, Unit Number 393 is used to control the output. If
the Exterior Horn is configured as a "General Purpose" output, Unit Number 394 is used to control the output. In this
configuration, Unit Numbers 393 and 394 should not be used as "Flags".
These 12 VDC voltage outputs are connected directly to the OmniPro II and not through a module. If you have something
connected to these outputs, such as a sprinkler system, your dealer will explain its operation. Outputs cannot be brightened or
dimmed and are
not
affected by All ON or All Off commands.
All On / Off
The All On/Off menu is used to turn all unit numbers in the specified House Codes on and off. When configured, the House
Code will affect 2 rooms of HLC or Vizia RF Z-Wave lighting (i.e. HC 1 ALL OFF affects Room 1 and 2).
Note: UPB, CentraLite, and RadioRA devices are not affected by the OmniPro II “All On” or “All Off” command. To achieve
this functionality, we suggest the following:
UPB:
Program a Link into each device that will respond to an OmniPro II “All On” and “All Off” command program. For
example:
In each UPB switch that will respond to “All Off” and “All On”, program a Link (in this example, Link 50 is used) that
will go to 100% when activated (turned on). Then write the following programs in the OmniPro II controller:
WHEN ALL ON: LINK 50 ON
WHEN ALL OFF: LINK 50 OFF
CentraLite
: Program the “All On” and “All Off” macro to execute an All On Scene and an All Off Scene on the CentraLite.
RadioRA
: Program the “All On” and “All Off” macro to execute Phantom Button 16 (All On) and Phantom button 17 (All Off).
For example:
WHEN ALL ON: PHANTOM BUTTON 16 ON
WHEN ALL OFF: PHANTOM BUTTON 17 ON
This All On/Off menu is also used to control Leviton Scenes, RadioRA Phantom Buttons, UPB Links, and CentraLite Scenes.
From the top-level display or from the main menu, press the 4 (ALL) key on the console keypad.
ALL
0=OFF
1=ON
2=SCN
3=LINK
↓
ALL
4=PHANTOM 5=CENLIT
↓
All Lights On
At the ALL prompt, press the 1 (LIGHTS ON) key. The console will beep, and a command will be sent that turns on all specified
X-10 and ALC units and HLC Rooms. X-10 Appliance Modules do not respond when the All Lights On command is sent. All
House Codes (1-16), by factory default, respond to the All-On command.
NOTE:
The All On function can be changed, if desired -
See
Set
Up Misc, All On And All Off
.
All Off
At the ALL prompt, press the 0 (OFF) key. The console will beep, and a command will be sent that turns off all specified X-10
and ALC units and HLC Rooms. All House Codes (1-16), by factory default, respond to the All-Off command.
NOTE:
The All Off function can be changed, if desired -
See
Set
Up Misc, All On And All Off
.