Page 42
The next series of displays shows the current analog reading for each security zone input. The displays show the readings for
zones 1-176.
1=147 2=148 3=147
4=146 5=146 6=147
THROUGH
175=148 176=147
↑
Normal readings for zones are between 137 - 157 when secure. If Zones 1-4 are configured as Fire or Gas zone, normal readings
are between 26 - 43 when secure. Each reading should be changing only by two or three counts from its average steady reading.
When a door or window is opened, the reading will go up to a value that represents that zone is open.
This feature can be used to monitor the quality of the zone wiring and contacts. If the numbers begin to deviate from their
original values when the system was new, wiring problems that will eventually lead to trouble or false alarms may be developing.
You may wish to record the Status Test values for future reference.
5 = TEMP (TEMPERATURE)
The Temperature Status menu allows you to view and scroll through the status of each Thermostat, PESM, and Temperature
Sensor. To enter the Temperature menu, from the Status menu, press the 5 key on the console keypad. The system will display:
TSTAT 1 TEMP:80
↓
HEAT:60 COOL:82
You may enter a unit number to start displaying the status with that unit, or simply press the down arrow key to scroll through the
list of temperature zones. The status display is as shown under Temperature Control, except that now the arrow keys may be used
to continue scrolling.
TSTAT
1
MODE: AUTO FAN: AUTO
At this point, you may press the ' # ' key to control the temperature zone as specified under Temperature Control.
6= ENERGY (ENERGY COST)
The Energy Cost Status menu allows you to view the current energy rate in use.
ENERGY
COST:
MID
The Energy Cost will display Lo, Mid, Hi or Crit (for critical) energy rates.
Summary of Contents for Omni Pro II
Page 2: ...Copyright 2001 2007 Home Automation Inc All Rights Reserved...
Page 107: ......